36
PART #
840923
840917
840919
TABLE 3: RECOMMENDED CLEANERS, LUBRICANTS AND SEALANTS
LUBRICANT/CLEANER
Christo-Lube MCG 111
Oakite #31
Loctite 425 or 480 Adhesive
Loctite 414 Superbonder
Loctite 242
Gasgacinch
White distilled vinegar
Non-ionic Liquid dishwashing
detergent (diluted with warm water)
TABLE 2: TORQUE SPECIFICATIONS
DESCRIPTION / KEY ITEM #
Plug, Valve (43)
Body, Valve (52)
Adapter, Metric, Valve Seat (50)
APPLICATION
All o-rings
CAUTION:
Silicone rubber requires no lubrication or preservative treatment. DO
NOT apply grease or spray to silicone rubber parts. Doing so may cause a chemical
breakdown and premature deterioration of the material.
Acid bath for reusable stainless steel and
brass parts.
CAUTION:
Do not use muriatic acid for the cleaning of any parts. Even if strongly
diluted, muriatic acid can harm chrome plating and may leave a residue that is harmful
to o-ring seals and other parts.
Component Adhesive
Sealant for hose
Acid bath for reusable stainless steel
and brass parts.
Degreaser for brass and stainless steel
parts; general cleaning solution for plastic
and rubber.
Odyssea (Export) Technical Manual
TORQUE
15 Nm (132 in lb)
30 Nm (22 ft lb)
10 Nm (89 in lb)
SOURCE
Aqua Lung
2340 Cousteau Court
Vista, CA 92081
Oakite Products, Inc.
50 Valley Road
Berkeley Heights, NJ 07922
Website Information
www.loctite.com
Website
www.gasgacinch.com
"Household" grade
"Household" grade

Advertisement