AIRWAY MAINTENANCE PROCEDURES

NOTE: Before performing any disassembly, refer to the
exploded parts drawing which references all mandatory
replacement parts. These parts should be replaced with
new and must not be reused under any circumstances
regardless of the age of the product or how much use it
has received since it was last serviced.
CAUTION: Use only a plastic or brass o-ring removal
tool when removing o-rings to prevent damage to the
sealing surface. Even a small scratch across an o-ring
sealing surface could result in leakage. Once an o-ring
sealing surface has been damaged, the part must be
replaced with new. DO NOT use a dental pick or any
other steel instrument.

Airway Disassembly

CAUTION: Protective eyewear must be worn when
servicing the airway.
1. Unscrew the retaining collar from the manifold to remove the
airway. Remove the gasket (12) from inside the manifold and
inspect it for damage. If no damage is found, it may be reused.
2. Using diagonal pliers, carefully remove the three clamps (22) from
the spiral hose (24) securing the inflator and dual valve assemblies.
CAUTION: Do not cut the spiral hose while removing
the clamp.
Odyssea (Export) Technical Manual
3. Pull back the spiral hose (24) from the airway body (30). Press
the pin (28) out from one side using a pin punch or similar tool to
release the braided spectra cord (23). Remove the spiral hose from
the dual valve body (13).
4. Using the spanner wrench to hold the push button (35), remove the
locknut (25) from the stem (31) with a 5.5mm nut driver. Use needle
nose pliers to remove the washer (26) and the rubber valve (27).
5. Using a flat blade screwdriver, carefully lift out the fingers of the
cage (36) and remove it from the airway body (30).
CAUTION: Do not apply excessive force or pry against
the airway body or cage with the tip of the screwdriver.
6. Remove the stem (31) through the front of the airway body (30).
Remove the mouthpiece (29) from the airway body.