Hayward HL32950VVSP Installation Manual
Hayward HL32950VVSP Installation Manual

Hayward HL32950VVSP Installation Manual

Vs omni pool automation control

Advertisement

VS Omni
Pool Automation Control
Installation Manual
HL32950VVSP HL32900VSP
HL26720VSP HL23520VSP
Hayward Pool Products
620 Division Street, Elizabeth NJ 07207
Phone (908)-355-7995
www.hayward.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Contents
Before you Begin.....................3
Mounting...............................7
Plumbing................................9
Wiring...................................10
Startup................................22
Configuration........................22
HL23510VSP
092680 RevB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HL32950VVSP and is the answer not in the manual?

Questions and answers

Summary of Contents for Hayward HL32950VVSP

  • Page 1 092680 RevB VS Omni Pool Automation Control Installation Manual Contents Before you Begin.....3 Mounting.......7 Plumbing........9 Wiring........10 Startup........22 Configuration......22 HL32950VVSP HL32900VSP HL26720VSP HL23520VSP HL23510VSP Hayward Pool Products 620 Division Street, Elizabeth NJ 07207 Phone (908)-355-7995 www.hayward.com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 2 (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by Hayward could void the user’s authority to operate this equipment.
  • Page 3: Table Of Contents

    Control Pad.......................7 Smart Relay......................8 Temperature Sensors..................9 Plumbing.........................9 Electrical Wiring High Voltage....................11 Low Voltage....................13 System Startup......................22 Configuration Pre Programmed Configuration................25 Typical Configuration..................25 Advanced Configuration..................27 Quick Edit......................42 Control Pad Mounting Template.................50 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 4: Before You Begin

    Accessory Products - Order Separately HLH485RELAY Smart Relay used for controlling additional pool equipment Flow Switch used to detect water flow GVA-24 Valve Actuator Temperature Sensor for 3rd input USE ONLY HAYWARD GENUINE REPLACEMENT PARTS USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 5: Overview

    Overview The Hayward VS Omni is a web enabled pool automation control with a convenient touchscreen interface. Because it's packaged with a high efficiency variable speed pool filter pump, the VS Omni is ideal for both retrofit and new pool/spa installations. Automatically and remotely control pumps, a heater, a valve actuator, pool and yard lighting, and more.
  • Page 6 Comm. to Comm. to Smart Relay 2 (15’) Controller (15’) Ethernet to Relay 1 (15’) Router Input Power to Smart Relay 1 To Solar Heater Filter Valve Actuator Variable Speed Pump FROM POOL POOL USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 7 The most common installation technique is described in the included Quick Start Guide. Use this guide if possible. If the Guide can not be applied to your particular installation, refer to the additional information in this manual. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 8: Control Pad

    54 . Tighten until the bottom of the screw heads are 1/8" off the mounting surface. Position the Control Pad cutouts over the screw and slide the unit downward. You may have to tighten or loosen the screws slightly to fully engage the screw heads to get a snug fit. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 9: Smart Relay

    Although this button is not functional during normal operation, mount the Smart Relay in an acces- sible location to use this feature in case of communication loss. Mount the Smart Relay to a wall or other flat surface using the mounting holes which are designed to accommodate #8 screws. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 10: Temperature Sensors

    Use additional cable (20 AWG) if necessary. Optional Valve Actuators Currently, using an Hayward GVA-24 actuator or equivalent requires that the Hub be powered with 230 VAC. If powering the VS Omni Hub with 115 VAC, an actuator can't be used. For installation, refer to the mounting instructions included with the unit.
  • Page 11: Electrical Wiring

    (see page 21) to seal this exit. Temperature Sensors, External Input & Heater Smart Relays & Control Pad Variable Speed Pump Communication Valve Actuators Flow Switch (Hub must be powered by 230 VAC) Input Power Ground Screw USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 12: High Voltage

    This configuration can be easily modified to power the VS Omni and the new VSP. Refer to the diagrams below. Existing Timeclock 230 VAC Disconnect from existing 230 VAC pump Connect to Hub and new Variable Speed Ground Pump (VSP) Wiring Whip to USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 13 The VS Omni pump requires a constant 230 VAC, 60Hz input power whether from the VS Omni Hub using the Wiring Whip or directly from a service panel/switch. Refer to the VS Omni Pump manual for the location of the wiring terminals as well as other related high voltage wiring information. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 14: Low Voltage

    (page 21) should be used to seal the channels's exit after wiring is complete. Do not run low voltage wiring through a knockout or with any high voltage wiring. Hayward Variable Speed Pump (VSP) Wiring A separate VSP pump manual has been included with the VS Omni. For low voltage communication wiring information, refer to the pump manual.
  • Page 15 The Hub utilizes 10K ohm thermistor type sensors with 15 ft cable. If a longer cable is required, con- tact the Hayward service dept. (908-355-7995) for information on suitable cable types and splices. Temperature sensors are wired to the 8 position connector shown on page 10 and on the follow- ing page.
  • Page 16 After properly configuring the VS Omni (see Configuration Wizard), the filter pump and/or desired pool equipment will be forced on or off when the external device is activated. SPST External Switch Either Normally Open or Normally Closed USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 17 (usually identified as “2-wire” remote control). For millivolt or line voltage heaters, contact Hayward Tech support, 908-355-7995. Refer to Heater the information on the following pages for more details on the con- nection to several popular heaters.
  • Page 18 Switch heater to either “Pool” or “Spa” (it doesn’t make any difference which is selected, the Hub will take control). Heater display should be “bO” (for “bypass On). Heater will start whenever Hub requests (when Hub “Heater” LED is illuminated). USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 19 “MODE” key on the heater keypad to put the control into “STANDBY” mode. Then press and hold both the “DOWN” and “MODE” keys for 3 seconds until the display shows the code “bo”. Orange Wire White Wire USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 20 “OFF” display and, thinking this is a mistake, change the mode to “POOL” or “SPA” which then disables the remote control by the Hub. To prevent this: Remove the heater Touchpad connector (P5) which will disable the touchpad. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 21 2. Remove upper jacket and open the control box. 3. Remove the jumper for the “fireman’s switch. 4. Wire to the Hub using wire rated for 105°C minimum. Transformer Fireman’s Switch Operating ‘Control Terminal Board 120 V STA-RITE USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 22 Hub. Work the gasket into the exit slot until it is fully sealed then fasten the cover to the Hub. Hub Cover (inside) Gasket Bottom of Hub Enclosure USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 23: System Startup

    There may be a newer version available and if so, we encourage you to upgrade. Also, if you have experienced problems, Hayward Technical Support may advise you to upgrade your VS Omni's firmware. To upgrade the VS Omni firmware, refer to the procedure shown in the VS Omni Operation Manual.
  • Page 24: Pre Programmed Configuration

    VS Omni. Navigation The Configuration Wizard has been designed to be intuitive allowing most users the ability to navi- gate with little instruction. Here are a list of commonly used buttons are explained: USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 25 Network Diagnostic screen will appear and the VS Omni will run through a series of checks to verify connection to the access point. Once the system is done running through the diagnostics, press the check mark to continue to the next section of the Configuration Wizard. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 26 %. If Speed in RPM is selected, then pump speeds will be displayed in RPM. Which Hayward Unique Address? Select the HUA of the filter pump. NOTE: this option only ap- pears if more than one variable speed pump is discovered.
  • Page 27 Select the type of pump driven accessory (water feature, cleaner, accessory) If Water Feature, Cleaner, or Accessory is selected: Which Hayward Unique Address? Select the HUA of the water feature, clean- er, or accessory’s variable speed pump. NOTE: this option only appears if more than two variable speed pumps are discovered.
  • Page 28 The VS Omni does not support more than one filter pump and heater for both the pool and spa. Do not make selections that allow more than one set of equipment. IMPORTANT: The following instructions are for Body of Water 1 (Pool) configuration. When finished USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 29 Filter Pump Off for Valve Change? When Yes is selected, the pump will shut off for 35 seconds whenever a valve changes position. Flow Monitoring Enabled? Requires use of a Hayward flow switch. This feature will help protect the filter pump from damage due to no flow. When Yes is selected, the VS Omni will monitor the state of water flow when the filter pump is on.
  • Page 30 Freeze Protect Speed? For two speed pumps only, select 50% or 100%. If VSP is selected: Which Hayward Unique Address? If using a VSP, you’ll be asked what is the Hayward Unique Address (HUA). If a value is already shown in the box, advance to the next screen.
  • Page 31 Advance to the next screen to continue gas heater configuration. If more than one heater has been configured: Heater Priority Duration? Set the amount of time that you will allow the priority heater (“1”) to heat before allowing the next heater to USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 32 Which Relay is it Wired to? Selecting the box will bring you to a table showing all detected relays. Select the high voltage relay that is wired to the pump (refer to the Connection Table in for this infor- USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 33 Type of Cleaner? Touch the box and select the type of cleaner used. Choices are Pres- sure, Suction, Robotic and In-Floor. Name of Cleaner - Touch the box and use the keyboard to name the cleaner. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 34 If VSP is selected: Which Hayward Unique Address? If using a VSP for your cleaner pump, you’ll be asked what is the Hayward Unique Address (HUA). If a value is already shown in the box, advance to the next screen. If no value is shown, selecting the box will bring you to a table show- ing all detected devices.
  • Page 35 Done. The relay(s) should now be shown in the box(es) and you can advance to the next screen to continue the pump configuration. If VSP is selected: Which Hayward Unique Address? If using a VSP for your water USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 36 Hayward Unique Address (HUA). If a value is already shown in the box, advance to the next screen. If no value is shown, selecting the box will bring you to a table showing all detected devices. Select the proper HUA from the table and touch the Done button.
  • Page 37 Select the proper relay(s) from the table and touch the Done button. The relay(s) should now be shown in the box(es) and you can advance to the next screen to continue the pump configura- tion. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 38 If VSP is selected: Which Hayward Unique Address? If using a VSP for your accessory pump, you’ll be asked what is the Hayward Unique Address (HUA). If a value is already shown in the box, advance to the next screen. If no value is shown, selecting the box will bring you to a table show- ing all detected devices.
  • Page 39 VS Omni can only support lights in Standalone mode using its high voltage relays. If Yes is selected: What Kind of Lights? Touch the box to select the type of lights that will be used. The options are UCL (14V), CL4.0 (115V), CL2.5 (14V), Incandescent, and Other. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 40 If Equipment to Equipment is selected: Select Interlock Statement - Use the right and left arrows to choose the de- sired behavior of the interlock. The behavior for each interlock statement is described below. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 41 Flow Switch detects no flow. Once the Flow Switch detects flow again, the Equipment is turned off and cannot be turned on again until the Flow Switch detects no flow. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 42 External Input becomes open again. The Equip- ment cannot be controlled independently. If the External Input is closed, the Equipment is forced off - The Equipment is always on until the External Input becomes closed, at which time the Equip- USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 43 If the Temp. Sensor reads greater than Temperature degrees F, the Equip- ment is forced off - The Equipment is always on until the Temp. Sensor reads greater than the selected Temperature set-point, at which time the Equipment USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 44 There are a number of additional buttons that appear in Quick Edit that either have functions unique to Quick Edit or do not appear anywhere else in the system. These buttons are as follows: USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 45 Type - Change the type of Filter Pump that is configured (Single Speed, 2-Speed, or VSP) HUA - Match the HUA (Hayward Unique Address) to the configured Filter Pump. This option only appears if the Filter Pump is configured as a variable speed pump.
  • Page 46 Select a Heater - Once you select a heater, all of the options for that heater will appear on the next screen. These options are as follows: Name - Create a custom name if desired. Type - Select the type of heater that is configured (Solar, Heat Pump, Gas). USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 47 Pump - Configure the cleaner pump, if used. Relay - Select the relay that is wired to the cleaner. This option only appears if the cleaner does not have an associated pump configured. Valve - Configure the cleaner valve, if used. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 48 2-Speed or VSP. Freeze Protect - Select whether you want the water feature to turn on for Freeze Protection. Also set the Freeze Protect air temperature threshold from this menu. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 49 Speed - Change the minimum and maximum allowed speeds of the accessory pump as well as the Low, Medium and High speed settings. This option only appears if the accessory pump is configured as a VSP. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 50 Select an Accessory - Once you select an accessory, all of the options for that Backyard accessory will appear on the next screen. These options are as follows: Name - Create a custom name if desired. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 51 These steps are described in the Advanced Configuration Guide section of this manual. Once an interlock has been created, the button will say “Interlocks”. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 52 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 53 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 54 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 55 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 56 Hayward is a registered trademark and Hub is a trademark of Hayward Industries, Inc. © 2017 Hayward Industries, Inc. All other trademarks not owned by Hayward are the property of their respective owners. Hayward is not in any way affiliated with or endorsed by those third parties.