Inspection and maintenance
07.2020
Adjusting emergency hoist limit switching, "top" (A)
The "top" operational hoist limit switching position must be set.
Actuate the UP-button in the control pendant with caution.
Observe the hoisting movement, until operational hoist limit switching (B) switches
off in the top hook position.
Actuate the override button (S260) in the control box and the UP-button at the same
time, until 0.39 in before the switch-off point (A).
– When using the option hook operated hoist limit switch (see section 4.12), this
must be overridden (keep the connecting rope under tension).
– Observe the minimum distance "a" between the hook block and the next obstacle,
see table, or hook aperture "C" - "c" (see section 7.15), depending on the
dimension at which the hook hangs lower.
– If the emergency hoist limit switch should switch off beforehand, turn the
adjustment screw "S1" clockwise 1 revolution and repeat step 4.
Turn the adjustment screw "S1" anticlockwise until the switch contact latches audibly.
Actuate the override button (S261) in the control box and the DOWN-button at the
same time to exit the switching area.
– The "top" emergency hoist limit switching position has been set.