Installation Direct Into Oem Product - Acuva STRIKE I Product Manual

Uv-led water disinfection module
Table of Contents

Advertisement

Installation Guide
Electrical Installation Steps Cont'd
INSTALLATION DIRECT INTO OEM PRODUCT CONT'D
Designator
table 5: Recommended components list for Strike I integration circuit.
table 6
application circuit as a function of other conditions.
Flow Switch
table 6: Truth table for interpretation of LED health output signal
Advanced UV-LED Water Purification |
Component
VCC
Power Supply
U1
78L05
U2
Strike Module
S1
Switch
Q1
2N3904
Q2
2N3904
R1
1.50kΩ, 0.5W
R2
1.50kΩ, 0.5W
R3
2.70kΩ, 0.5W
R4
22.1kΩ, 0.125W
LED1
Coloured LED
LED2
Coloured LED
indicates the behavior of the LED health indication output of the
LED Health
Open
X
Closed
Healthy
Closed
Fault
acuvatech.com
Strike I and II UV-LED Water Disinfection Module
Description
12-24V
5V Voltage Regulator
UVC-LED Water Disinfection Unit
Closes when water flowing
Saturated during normal operation, conducting
LED1
Saturated during normal operation, shorting
LED2
Current set resistor for normal operation
indicator LED1
Current set resistor for fault operation indicator
LED2
Current set resistor for Q1 & Q2
Q1 & Q2 Base pulldown resistor
Lit when UV LED is working within normal
parameters
Lit when UV LED is in a fault condition
LED1
LED2
OFF
ON
OFF
P R O D U C T M A N U A L
OFF
OFF
ON
Page 13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strike ii

Table of Contents