Strike Electrical Characteristics - Acuva STRIKE I Product Manual

Uv-led water disinfection module
Table of Contents

Advertisement

Product Information

Strike Electrical Characteristics

The Strike modules electrically interfaces via a 4-wire terminated connector
protected with an outer PVC jacket. See
dimensions of the cable.
The electrical signal family of the Strike module is accessed via a
connectorized, jacketed cable. See
opto-electronic head have one connectorized lead while Strike II modules
with two opto-electronics heads have two identical connectorized leads.
*
* Wire colour can be Blue/Yellow or Green
Figure 3: Strike family signal family and connector
The electrical characteristics of the Strike module IO are listed in detail in
table
VCC is the power input to the module.
The enable is an input to the module to trigger the UV-LED to activate.
The health indicator is an output from the module signalling the module's
LED health status.
Ground acts as the return for VCC and the reference for the indication
and enable signal.