Acuva STRIKE I Product Manual page 7

Uv-led water disinfection module
Table of Contents

Advertisement

Product Information
Strike Electrical Characteristics Cont'd
LED Health
Indicator (IND)
Enable (EN)
table 3: Electrical characteristics of Strike module
IND net contains an internal 5.1kΩ pullup resistor
1
VCC will be present on the LED Health Indicator pin when the module is enabled and LED is healthy.
1
LED Health Indicator will be 0.15V in all other conditions.
EN net contains an internal 510Ω pulldown resistor
2
WARNING
Do not exceed maximum electrical ratings for any electrical IO position.
Strike UV-LED electronics always require proper protections respecting
these ratings. See section
for details on proper electrical integration.
Electrostatic Discharge (ESD)
table 4: Absolute maximum electrical ratings
Advanced UV-LED Water Purification |
Net
Max. Input Voltage
Min. Input Voltage
VCC
Max. Current Draw vcc = 12v
Min. Current Draw vcc = 24v
Normal Operation Output Voltage
Fault Operation Output Voltage
1
Maximum Normal Operation Current
Maximum Fault Current
Maximum Input Voltage for Operation
2
Minimum Input Voltage for Operation
Input Voltage
Reverse Input Voltage
Enable Pin Voltage
Water Temperature
Ambient Temperature
Water Flow Rate
acuvatech.com
Strike I and II UV-LED Water Disinfection Module
Condition
electrical installation overview steps
Absolute Maximum Rating
2.0 kV (HBM)
Value
Unit
30
V
11
V
0.5
A
0.25
A
VCC
V
0.150
V
3.5
mA
-20
mA
5.0
V
2.5
V
30V
0.3V
5.5V
45
C
o
55
C
o
4.0 LPM