Download Print this page

Lowara E6 PWM Series Installation And Operating Instructions Manual page 4

For heating and cooling application

Advertisement

Rated connection
For pipe thread
width DN
25
1"
Installation length (see fig. 1): 180 mm
3.
Dimensions (see figure 1)
4.
Technical Specifications
Motor model
Rated voltage
Frequency
Power consumption
IP protection
Insulation class
Max. system pressure
Permitted temperature
range of pumped fluid
Permitted pumping
media
*
Must not freeze. To avoid condensation the fluid temperature
must always be higher than the ambient temperature.
** Performance of the pump will noticeably change when pumping
water/glycol mixtures with concentrations higher than 20%.
Pump connection
thread
G 1 ½"
Electronically commutated spherical motor
with permanent magnet rotor
E6 PWM7.. NIBE
E6 PWM7..NIBE ST2
230 V
230 V
50/60 Hz
50/60 Hz
9-75 W
9-110 W
IP 42
IP 42
Class F
Class F
10 bar
10 bar
-10 ° C*to +95 ° C
-10 ° C* to +60 °C
Heating water according to VDI 2035,
water/glycol mixtures**
4

Advertisement

loading

This manual is also suitable for:

E6 pwm7