Removing the Holding Charge

I I m m p p o o r r t t a a n n t t : : Safety precautions must be followed. Refer to U U n n i i t t I I n n s s t t a a l l l l a a t t i i o o n n H H a a z z a a r r d d s s in the S S a a f f e e t t y y P P r r e e c c a a u u t t i i o o n n s s section
of this manual before proceeding.
N N o o t t e e : : Always keep the holding charge in the condensing unit and the remote evaporators until ready to connect the
tubing.

Condensing Unit

Slowly remove the ORS caps from the hot gas, liquid and suction lines at rear of the condensing unit to release the
nitrogen holding charge.

Remote Evaporators

Slowly remove the solder caps from the hot gas, liquid and suction lines at rear of each evaporator to release the
nitrogen holding charge.
TK 56701-1-IM-EN
Figure 37. ORS and Solder Cap Locations Shown