Wall And Ceiling Troughs - Trane Thermo King SPECTRUM T-90 Series Installation Manual

Self-powered truck edition multi-temperature systems
Table of Contents

Advertisement

Wall and Ceiling Troughs

Thermo King recommends enclosed wall or ceiling troughs be used for SPECTRUM multi-temperature applications.
Troughs not only protect refrigeration tubes and electrical harnesses from damage, but also help prevent air leakage
between compartments.
The following installation standards are recommended:
Only one trough (Wall or Ceiling) is required.
Refrigeration tubes should be routed neatly in the trough.
Refrigeration tubes should be secured by clamps every 600 mm (24.00 in.) inside the trough.
Electrical harness should be secured by clamps or tie bands every 600 mm (24.00 in.) inside the trough.
Insulate all hot gas and suction refrigeration tubes inside the trough.
Trough covers are recommended to protect refrigeration tubes and electrical harnesses from damage.
203 mm
(8.00 in.)
1.
Suction Tube
2.
Hot Gas Tube
TK 56701-1-IM-EN
Figure 33. Refrigerant Tubing and Electrical Wiring Details Shown
1
1
2
3
4
36 mm
(1.40 in.)
E E v v a a p p o o r r a a t t o o r r I I n n s s t t a a l l l l a a t t i i o o n n S S t t a a n n d d a a r r d d s s
4
3
RCS1140-3
3.
Liquid Tube
4.
Electrical Harnesses
1
1
2
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thermo king spectrum t-1090

Table of Contents