Defrost Drain Tube Connectors - Trane Thermo King SPECTRUM T-90 Series Installation Manual

Self-powered truck edition multi-temperature systems
Table of Contents

Advertisement

Defrost Drain Tube Connectors

I I m m p p o o r r t t a a n n t t : : Follow the instructions below to prevent defrost drain tube water leaks.
All Spectrum remote evaporators are equipped with a quick disconnect fitting that connects the drain pan to the drain
tubes. To properly install the tube make sure that the tube is fully inserted past the O-ring and up to the stop inside the
coupler
N N o o t t e e : : The fitting will grip the tube before it seals with the O-ring.
When the tube is in the correct position the O-ring will seal and the teeth will grip the tube keeping it in place. Check the
fit by pulling on the tube(s) to insure that it will not pull out of the fitting.
To disconnect the tube from the fitting: press the collet into the fitting. Hold the collect in place and pull the tube out.
The fitting can be re-used. Clean any burrs off the tube before re-inserting it into the fitting.
1.
O-Ring
2.
Collet
TK 56701-1-IM-EN
Figure 34. Defrost Drain Tube Connectors Shown
1
2
4
3
E E v v a a p p o o r r a a t t o o r r I I n n s s t t a a l l l l a a t t i i o o n n S S t t a a n n d d a a r r d d s s
3.
Stainless Steel Teeth
4.
Stop
AAA164-1
53