Evaporator Installation Standards
I I m m p p o o r r t t a a n n t t : : Safety precautions must be followed. Refer to the S S a a f f e e t t y y P P r r e e c c a a u u t t i i o o n n s s section of this manual before
proceeding.
This section defines the Thermo King installation standards to correctly and safely install the SPECTRUM remote
evaporators for multi-temperature refrigeration system. Proper installation of each evaporator is critical. Improper
installation can not only result in poor system performance, but it can also become a safety concern. It is the
responsibility of the installer to follow these standards to assure the components are installed correctly and the unit
operates as designed.

Evaporator Locations

Refer to the illustration below.
Best airflow is achieved when an evaporator is installed an equal distance from each wall.
It is recommended that moving bulkheads are not allowed closer than 1219 mm (48.00 in.), or one pallet from the
evaporator outlet.
Minimum clearance from bottom of evaporator to top of cargo should be 101 mm (4.00 in.)
N N o o t t e e : : This minimum clearance is required under the fan intake area only and does not refer to the cargo box L L O O A A D D
L L I I N N E E .
Evaporator should be located a minimum of 51 mm (2.00 in.) from truck cargo box wall.
1.
Drain tube located inside cargo box wall
46
Figure 31. Evaporator Location Dimensions Shown
1219 mm
(48.00 in.)
101 mm
(4.00 in.)
51 mm
(2.00 in.)
2.
Truck cargo box wall
25 mm
(1.00 in.)
RCS1138-1
1
2
TK 56701-1-IM-EN