Installation Procedures - Trane Thermo King SPECTRUM T-90 Series Installation Manual

Self-powered truck edition multi-temperature systems
Table of Contents

Advertisement

Installation Procedures

I I m m p p o o r r t t a a n n t t : : Safety precautions must be followed. Refer to U U n n i i t t I I n n s s t t a a l l l l a a t t i i o o n n H H a a z z a a r r d d s s in the S S a a f f e e t t y y P P r r e e c c a a u u t t i i o o n n s s section
of this manual before proceeding.
P P r r e e f f e e r r r r e e d d I I n n s s t t a a l l l l a a t t i i o o n n M M e e t t h h o o d d — Thermo King recommends the four (4) factory installed nut plates attached inside
the frame along with the correct length hex head grade 5 mounting bolts (installer supplied) be used when installing the
unit.
If your installation requires the nut plates be removed, see " " A A l l t t e e r r n n a a t t e e I I n n s s t t a a l l l l a a t t i i o o n n M M e e t t h h o o d d " " on the next page.
N N o o t t e e : : Do not install any compressible washers or other materials between the unit and the truck!
1. Position condensing unit into cargo box opening. Do not pull on the drain hoses or electrical wires during the
installation.
2. From inside the cargo box, insert four (4) correct length mounting bolts with four (4) 2.00" OD flat washers
(supplied) through the front wall of the box and into the unit's mounting nuts.
a. Apply blue thread locker to all four (4) unit mounting bolts.
b. Tighten the mounting bolts evenly and then torque to 81.4 N•m (60 ft-lbs).
3. Disconnect and remove lifting bar and eyebolts from unit.
4. Install the exhaust extension tube pointing towards rear of truck and tighten securely.
4
1
TK 56701-1-IM-EN
Figure 22. Typical Installation Shown
3
I I n n s s t t a a l l l l i i n n g g C C o o n n d d e e n n s s i i n n g g U U n n i i t t
2
RCS1137-3
37