Warranty is based on the general guide to good practice in the pressure tested, dehydrated, charged terms and conditions by country. The installation by the installer of TTD/TTT and run tested before shipment. warranty is void if the equipment is mini-split system. Installation...
Contents General Information Valid System Combinations Installation Requirements Location and Preparation of Units Connection of Refrigerant Tubing Condensate Drain Piping System Evacuation and Purging Electrical Installation Matching Table Wiring Diagram Dimensional Data Note MS-SVN005-EN S - S V N 0 0 5 - E N . i n d d 3 1 / 1 0 / 0 8 1 1 : 0 3 : 2 8 A...
Installation Requirements 1. Copper Tubing - Purchase equal lengths of both 2. Additional Materials Copper tubing, fittings and tubes and insulation required. - Saddles or clamps to hold insulation to interconnect the Cut the appropriate tube lengths, refrigerant tubing. suction (S) (wide tube) and liquid 30 to 40 cm (12 to 16 in.) longer - Insulated clamps or staples (L) (narrow tube) refrigerant lines...
Location and Preparation of Units 1. Choose a place as cool as possible. Air Discharge Air Inlet The place should be well ventilated and the inlet air should not hotter 1,200 mm (48") 200 mm (10") than the outside temperature (max C or 113 2.
Connection of Refrigerant Tubing 1. The principal concerns in refrigeration tubing are: - Uniform oil return to the Electrical Connection compressor. - Pressure drops and their effect on Liquid Line System # 1 Service Port system capacity. Gas Line System # 1 - Tube routing and isolation to avoid Liquid Line System # 2 line breakage, vibration and sound...
Condensate Drain Piping 1. The drain hose should come straight down the wall to a level where runoff will not stain the wall. 2. There should be no traps and avoid putting the end of the hose in water. 3. To avoid damage to the floor or furniture when the drain hose is placed in the room, insulate the hose with foamed polyethylene...
System Evacuation and Purping The outdoor unit is factory charged. Indoor Unit 3 Unit nameplate charge is the total required system charge with 7.5 meters of interconnecting lines. Since the outdoor unit will not have to be evacuated unless charge has been Indoor Unit 2 completely lost, leave the suction and liquid shut-off valves closed.
Electrical Installation Wiring and grounding must comply Checking the system before start up with national and local codes. Once the unit is installed, a check of Wiring the system is recommended before Important Safeguards: starting the units. - Check the unit nameplate for - Check that field connections are electrical rating.
Dimensional Data Model TTT521 MS-SVN005-EN S - S V N 0 0 5 - E N . i n d d 1 4 1 / 1 0 / 0 8 1 1 : 0 3 : 3 5 A...
Page 15
Dimensional Data Model TTD527 TTT527 OUTLINE DRAWING TTD530 TTT530 TTD533 TTT533 TTD536 TTT536 TTD539 TTT539 TTD542 TTT542 MOUNTING DETAIL OUTDOOR UNIT 1.18 (30.0) 42.0 (1068.0) SLOTS 10.0 x 25.0 (MM.) 0.78 (20.0) AIR FLOW DIRECTION POWER SUPPLY 14.17 Ø1-3/16 (30.0 MM.) (360.0) 13.0 42.0 (1068.0)
Page 16
Dimensional Data Model TTD518 TTD521 TTD524 MS-SVN005-EN S - S V N 0 0 5 - E N . i n d d 1 6 1 / 1 0 / 0 8 1 1 : 0 3 : 3 6 A...
Page 17
Dimensional Data Model TTD545 TTT545 TTD548 TTT548 TTD551 TTT554 TTD554 MS-SVN005-EN S - S V N 0 0 5 - E N . i n d d 1 7 1 / 1 0 / 0 8 1 1 : 0 3 : 3 6 A...