v01.0910
PLLs WITH INTEGRATED VCO - MICROWAVE APPLICATIONS
EVALUATION BOARD OPERATING GUIDE
4.3.3
ActiveA Loop Filter
a
the activea loop filter consists of c62, r3, c63, r21, c61, r14, r15, c60 and op-amp u5. it can be
configured by removing c33, c37, c64, r4, r12, r13, r22, shorting r25, r26, JP6, and powering +15V
on.
Figure 7. ActiveA Loop Filter
Order On-line at
www.hittite.com
For technical application questions: Phone: 978-250-3343 or
pll@hittite.com
A - 9