Panasonic AV-UHS500P Operating Instructions Manual page 151

Live switcher
Table of Contents

Advertisement

Specifications
Synchronizing connectors
<REF> terminal
Reference input/
BB outputs
Video delay time
Control connectors
<LAN> terminal
<TALLY GPI> terminal
Other
Ambient operating
temperature
Ambient operating
humidity
Storage temperature
Storage humidity
Mass
Dimensions
(W × H × D)
In Genlock mode: Black burst or Tri-level Sync input signals (with loop-through)
p p Loop-through output is performed in external sync mode.
p p If loop-through output is not going to be used, provide a 75 Ω termination.
p p Connectors : BNC
p p Same field frequencies as those of the system formats supported.
p p With the 1080/24PsF format, only Genlock mode supported.
p p With the 1080/23.98PsF format, black burst with 10 Field ID (SMPTE318M standard met) or Tri-
level Sync signals supported.
p p BB signals are output from two connectors in the internal sync mode.
1 line (H)
When the frame synchronizer setting is [Off] and neither the up-converter nor the
down-converter is operating
1 frame (F)
When the frame synchronizer setting is on and the up-converter and down-
converter are operating
p p When the signals have passed through PinP, DVE, multi view, down-converter or HDMI IN, a
maximum delay of 1 frame is applied in each case.
Compatible with 1000Base-TX and AUTO-MDIX (For IP control)
p p Connecting cable: LAN cable (CAT5E), max. 100 m (328 ft), STP (Shielded Twisted Pair) cable
recommended
p p Connectors : RJ-45
INPUT: 8 inputs, general-purpose, photocoupler sensing
OUTPUT: 19 outputs, selected from R/G tally, general-purpose
ALARM: 1 output, open collector output (negative logic)
0 °C to 40 °C (32 °F to 104 °F)
10% to 90% (no condensation)
0 °C to 40 °C (32 °F to 104 °F)
10% to 90% (no condensation)
Approx. 7 kg (15.4 lb)
440 mm × 170 mm × 360 mm (17-5/16 inches × 6-11/16 inches × 14-3/16 inches) (excluding
protrusions)
151