ADJ ENCORE PROFILE 1000 WW User Instructions page 6

Hide thumbs Also See for ENCORE PROFILE 1000 WW:
Table of Contents

Advertisement

DMX SET UP (continued)
lighting stores). Your cables should be made with a male and female XLR connector on either end of the
cable. Also remember that DMX cable must be daisy chained and cannot be split.
Notice: Be sure to follow figures two and three when making your own cables. Do not use the ground lug on
the XLR connector. Do not connect the cable's shield conductor to the ground lug or allow the shield conductor
to come in contact with the XLR's outer casing. Grounding the shield could cause a short circuit and erratic
behavior.
Figure 3
Special Note: Line Termination. When longer runs of cable are used, you may need to use a terminator on
the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is connected
between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR
connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number
Z-DMX/T) will decrease the possibilities of erratic behavior.
5-Pin XLR DMX Connectors. Some manufactures use 5-pin DMX-512 data cables for DATA transmission in
place of 3-pin. 5-pin DMX fixtures may be implemented in a 3-pin DMX line. When inserting standard 5-pin
data cables in to a 3-pin line a cable adaptor must be used, these adaptors are readily available at most
electric stores. The chart below details a proper cable conversion.
Conductor
Ground/Shield
Data compliment (- signal)
Data True (+ signal)
Not used
Not used
A.D.J. Supply Europe B.V. – www.americandj.eu – Encore Profile 1000 WW Instruction Manual Page 6
Termination reduces signal errors and avoids
signal transmission problems and interference.
It is always advisable to connect a DMX
terminal, (Resistance120 Ohm 1/4 W) between
PIN 2 (DMX-) and PIN 3 (DMX +) of the last
fixture.
3-Pin XLR to 5-Pin XLR Conversion
3-pin XLR Female (Out)
Pin 1
Pin 2
Pin 3
Figure 2
XLR Pin Configuration
Pin1 = Ground
Pin2 = Data Compliment (negative)
Pin3 = Data True (positive)
Figure 4
5-pin XLR Male (In)
Pin 1
Pin 2
Pin 3
Do Not Use
Do Not Use