Advertisement

Quick Links

15 HEX BAR IP
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for ADJ 15 HEX BAR IP

  • Page 1 15 HEX BAR IP User Manual...
  • Page 2 Products, LLC brands and product names are trademarks or registered trademarks of their respective companies. ADJ Products, LLC and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Introduction Features | Warranty Registration Safety Precautions IP65 Notice Overview Installation Manual Tilt Adjustment | Connections DMX Set Up System Menu DMX Addressing DMX Traits Color Macro Chart Pixel Zones | Dimmer Curves Chart Primary-Secondary Configuration Glare Shield Installation | Filter Installation Dimensional Drawing Multi Unit Power Linking | Trouble Shooting | Cleaning Limited Warranty (USA Only)
  • Page 4: Introduction

    Introduction: The 15 Hex Bar IP is a DMX intelligent, IP rated LED wash fixture. This fixture can be used in a stand alone mode or connected in a Primary/Secondary configuration. This product is intended to be used by professionally trained personnel only and is not suitable for private use.
  • Page 5: Features | Warranty Registration

    • 2 x Omega Brackets WARRANTY REGISTRATION The 15 Hex Bar IP carries a 2 year limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items, whether under warranty or not, must be freight pre-paid and accompanied by a return authorization (R.A.) number.
  • Page 6: Safety Precautions

    SAFETY PRECAUTIONS • Do not attempt to operate this unit if the power cord has been frayed or broken. • Do not attempt to remove or break off the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and fire in the event of an internal short. •...
  • Page 7 SAFETY PRECAUTIONS RISK GROUP 3 - RISK OF EXPOSURE TO ULTRAVIOLET (UV) RADIATION! FIXTURE EMITS HIGH INTENSITY ULTRAVIOLET (UV) LIGHT. WEAR PROPER EYE AND SKIN PROTECTION. AVOID PROLONGED PERIODS OF EXPOSURE. AVOID WEARING WHITE COLOR CLOTHING AND/OR USING (UV) PAINTS ON SKIN. AVOID DIRECT EYE AND/OR SKIN EXPOSURE AT DISTANCES SHORTER THAN 11 feet (3.3m).
  • Page 8: Ip65 Notice

    IP65 NOTICE IP65 RATED An IP rated lighting fixture is commonly installed in outdoor environments and has been designed with an enclosure that effectively protects the ingress (entry) of external foreign objects such as dust and water. The Ingress Protection (IP) rating system is commonly expressed as “IP” followed by two numbers (i.e.
  • Page 9: Overview

    OVERVIEW...
  • Page 10: Installation

    (available at most electrical suppliers) to prevent water ingress/condensation and/or corrosion. The 15 Hex Bar IP is fully operational in three different mounting positions: hanging upside-down, mounted sideways on trussing, or set on a flat level surface. Be sure this fixture is kept at least 12m (40ft) away from any flammable materials (decoration etc.).
  • Page 11 INSTALLATION NOTE: Safety cable attachment points are located at both ends. Its recommended to use safety cables on both ends. ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING THIS DEVICE IN A SUSPENEDED ENVIRONMENT IN ORDER TO ENSURE THE FIXTURE WILL NOT FALL IF THE CLAMP FAILS.
  • Page 12: Manual Tilt Adjustment | Connections

    MANUAL TILT ADJUSTMENT The bar angle is adjustable manually using the brackets located on each side of the unit. Simply loosen the tilt adjustment knobs attached to each mounting bracket and adjust the bracket accord- ingly. After making your desired set up, securely tighten the tilt adjustment knobs. The image below illustrates a 90-degree configuration.
  • Page 13: Dmx Set Up

    DMX-512 protocol. The 15 Hex Bar IP has 10 DMX channel modes. The DMX address is set on the back panel of the 15 Hex Bar IP. Your unit and your DMX controller require a standard 5-pin XLR connector for data input and data output. We recommend Accu-Cable DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all pro lighting stores).
  • Page 14: System Menu

    SYSTEM MENU The fixture includes an easy to navigate system menu control panel display where all necessary settings and adjustments are made. During normal operation, pressing the MENU button once will access the fixture’s main menu. Once in the main menu, you can navigate through the different functions and access the sub-menus with the UP and DOWN buttons.
  • Page 15 SYSTEM MENU 001 - 512 Address Set DMX address 12ch 14ch 17ch Ch. Mode Set DMX mode 30ch 33ch 38ch DMX SET 41ch 60ch Hold last channel values received Hold before DMX signal was lost Take all channels No DMX Blackout to 0 when DMX signal is lost...
  • Page 16 SYSTEM MENU Gamma 1 - 10 Save Dlay Time interval of Display Off, 1min - 10min Lock inactivity before PERSONALITY screen locks (continued) Red 000 - 255 Green 000 - 255 Blue 000 - 255 Calibrat White 000 - 255 Service Passcode = 011 Amber 000 - 255...
  • Page 17 SYSTEM MENU Total hours fixture has been pow- Pwr On Hr 1 xxxxxx Hours ered on. Non resettable Hours fixture has Hours Pwr On Hr 2 xxxxxx Hours been powered on since last reset Allows Pwr On Hr Pwr On Rst Passcode = 050 2 to be reset to zero...
  • Page 18: Dmx Addressing

    DMX ADDRESSING All fixtures should be given a DMX starting address when using a DMX controller, so the correct fix- ture responds to the correct control signal. This digital starting address is the channel number from which the fixture starts to “listen” to the digital control signal sent out from the DMX controller. The assignment of this starting DMX address is achieved by setting the correct DMX address on the digi- tal control display on the fixture.
  • Page 19: Dmx Traits

    DMX TRAITS CHANNEL FUNCTION VALUES 9CH 12CH 14CH 17CH 30CH 33CH 38CH 41CH 60CH 000 - 255 All Red, 0% to 100% 000 - 255 All Red Fine 000 - 255 All Green, 0 % to 100% 000 - 255 All Green Fine 000 - 255 All Blue, 0% to 100% 000 - 255 All Blue Fine 000 - 255 All White, 0% to 100%...
  • Page 20 DMX TRAITS CHANNEL FUNCTION VALUES 9CH 12CH 14CH 17CH 30CH 33CH 38CH 41CH 60CH 000 - 255 UV 2 Fine 000 - 255 Red 3, 0% to 100% 000 - 255 Red 3 Fine 000 - 255 Green 3, 0% to 100% 000 - 255 Green 3 Fine 000 - 255 Blue 3, 0% to 100% 000 - 255 Blue 3 Fine...
  • Page 21 DMX TRAITS CHANNEL FUNCTION VALUES 9CH 12CH 14CH 17CH 30CH 33CH 38CH 41CH 60CH 000 - 255 UV 5, 0% to 100% 000 - 255 UV 5 Fine Color Macros, see Color Macros Chart section of this 000 - 255 manual Color Temperature, 2700K - 000 - 255...
  • Page 22 DMX TRAITS CHANNEL FUNCTION VALUES 9CH 12CH 14CH 17CH 30CH 33CH 38CH 41CH 60CH Auto Programs Speed, slow 000 - 255 to fast Auto Programs Fade, least 000 - 255 fade to most fade Dim Mode 000 - 020 Standard 021 - 040 Stage 041 - 060 TV 061 - 080 Architectural...
  • Page 23 DMX TRAITS CHANNEL FUNCTION VALUES 9CH 12CH 14CH 17CH 30CH 33CH 38CH 41CH 60CH Refresh Rates (continued) 046 - 060 1100 Hz 061 - 075 1200 Hz 076 - 090 1300 Hz 091 - 105 1400 Hz 106 - 120 1500 Hz 121 - 135 2500 Hz 136 - 150 4000 Hz 151 - 165 5000 Hz...
  • Page 24: Color Macro Chart

    COLOR MACRO CHART COLOR INTENSITY COLOR NUMBER VALUE GREEN BLUE WHITE AMBER Color1 001 - 004 Color2 005 - 008 Color3 009 - 012 Color4 013 - 016 Color5 017 - 020 Color6 021 - 024 Color7 025 - 028 Color8 029 - 032 Color9...
  • Page 25 COLOR MACRO CHART COLOR INTENSITY COLOR NUMBER VALUES GREEN BLUE WHITE AMBER Color34 133 - 136 Color35 137 - 140 Color36 141 - 144 Color37 145 - 148 Color38 149 - 152 Color39 153 - 156 Color40 157 - 160 Color41 161 - 164 Color42...
  • Page 26: Pixel Zones | Dimmer Curves Chart

    PIXEL ZONES DIMMER CURVE CHART...
  • Page 27: Primary-Secondary Configuration

    PRIMARY-SECONDARY CONFIGURATION This function will allows you to link units together to run in a Primary-Secondary set-up, in which one unit will act as the controlling unit and the others will react to the controlling unit’s built-in programs. Any unit can act as a Primary or as a Secondary, but only one unit can be programmed to act as the “Primary.”...
  • Page 28: Glare Shield Installation | Filter Installation

    GLARE SHIELD INSTALLATION The 15 Hex Bar IP comes with an attachable glare shield. The glare shield can easily be installed by following the directions below. If you have any questions regarding installation, please contact ADJ customer support. 1. Locate the three (3) screw holes located on either side of the unit.
  • Page 29: Dimensional Drawing

    DIMENSIONAL DRAWINGS...
  • Page 30: Multi Unit Power Linking | Trouble Shooting | Cleaning

    MULTIPLE UNIT POWER LINKING With this feature you can link the fixtures to one another using the power cable input and output sockets. The maximum number of units that can be linked in this manner is as follows: • 6 units with 120V power. •...
  • Page 31: Limited Warranty (Usa Only)

    LIMITED WARRANTY (USA ONLY) A. ADJ Products, LLC hereby warrants, to the original purchaser, ADJ Products, LLC products to be free of manufacturing defects in material and workmanship for a prescribed period from the date of purchase (see specific warranty period on reverse). This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories.
  • Page 32: Specifications

    SPECIFICATIONS Light Source: • LED: 15x 12W HEX (6-In-1) RGBWA+UV LEDs (50,000 hr.) • Beam Angle: 25-degrees • LUX: 14541 @ 1M, 582 @ 5M (Full On No UV); 14517 @ 1M, 581 @ 5M (Full On) Features: • IP65 rated – protects from dust, sand, moisture and liquid •...

Table of Contents