Table 205. Main Processor Troubleshooting Chart (Continued)
Item
Function Type
ID
Non−Volatile Memory
A007
BITE Task
SEEP-
ROM
A007
BITE Task
SEEP-
ROM
A007
BITE Task
SEEP-
ROM
A008
Timing
− RTC
Timing
Timing
B009
Audio I/P
− Ana-
log
Audio
Input 1
Use or disclosure of information on this sheet is subject to
The document reference is online, please check the correspondence between the online documentation and the printed version.
the restrictions on the cover page of this document.
AVIATION RECORDERS
COMPONENT MAINTENANCE MANUAL
Model FA5000
Failure
Local Effect
Mode
Electrical In-
Software glitch
terference
flips data bits,
causing data
corruption
such as lost,
missing or
scrambled
data
Loss of
The SEEP-
Power
ROM fails: Un-
able to perform
BITE Test
Over/Under
The SEEP-
Voltage
ROM fails: Un-
able to perform
BITE Test
Electrical In-
Software glitch
terference
flips data bits,
causing data
corruption
such as lost,
missing or
scrambled
data
Loss of
The Real Time
Power
Clock fails: Un-
able to set/get
the date and
time
Over/Under
The Real Time
Voltage
Clock fails: Un-
able to set/get
the date and
time
Electrical In-
Software glitch
terference
flips data bits,
causing data
corruption
such as lost,
missing or
scrambled
data
Audio I/P Ch
No Audio to
1 is open
Ch 1
Next Effect
End Effect
The MP PWA
The CVDR does not operate
does not oper-
properly and may have corrup-
ate properly
ted data
and may have
corrupted data
Status of the
Status of the CVDR is not cur-
CVDR is not
rent and the Fault Log is not
current and the
updated
Fault Log is not
updated
Status of the
Status of the CVDR is not cur-
CVDR is not
rent and the Fault Log is not
current and the
updated
Fault Log is not
updated
The MP PWA
The CVDR does not operate
does not oper-
properly and may have corrup-
ate properly
ted data
and may have
SEEPROM resets and is able
corrupted data
to keep track of the current
status of the recorder and
manage the Fault Log
The CVDR has
The CVDR has no valid time
no valid time
stamp or date
stamp or date
The CVDR has
The CVDR has no valid time
no valid time
stamp or date
stamp or date
The CVDR
The CVDR does not have the
does not have
correct time stamp and date
the correct time
stamp and
resumes operating with the de-
date
faulted time and date of the
next power cycle
Ch 1 is unable
Ch 1 is unable to record audio
to record audio
23–70−40
FDR Function Testing & Fault Isolation
Rev. 03 Page 226
Rev.04 Page 226