L3 FA5000 Component Maintenance Manual With Illustrated Parts List page 115

Cockpit voice and data recorder
Hide thumbs Also See for FA5000:
Table of Contents

Advertisement

Table 204. Aircraft Interface Troubleshooting Chart (Continued)
Pin
Signal Type
ID
27
ARINC 429
O/P (­)
28
ARINC 429
O/P (+)
28
ARINC 429
O/P (+)
29
Discrete
29
Discrete
30
Discrete
30
Discrete
31
Ground
31
Ground
32
Differential
ARINC429 (­)
32
Differential
ARINC429 (­)
33
Differential
ARINC717 (­)
33
Differential
ARINC717 (­)
34
Differential
ARINC717 (­)
Use or disclosure of information on this sheet is subject to
The document reference is online, please check the correspondence between the online documentation and the printed version.
the restrictions on the cover page of this document.
AVIATION RECORDERS
COMPONENT MAINTENANCE MANUAL
Model FA5000
Signal Function
Failure Mode
ARINC 429 Output
The signal path is
Low
shorted
ARINC 429 Output
The signal path is
High
open
ARINC 429 Output
The signal path is
High
shorted
FDR Input Data Rate
The signal path is
Program A
open
FDR Input Data Rate
The signal path is
Program A
shorted
FDR Input Data Rate
The signal path is
Program B
open
FDR Input Data Rate
The signal path is
Program B
shorted
Res Area Microphone
The signal path is
Power Shield Ground
open
Res Area Microphone
The signal path is
Power Shield Ground
shorted
ARINC 429 Input Low
The signal path is
open
ARINC 429 Input Low
The signal path is
shorted
FDR Data Input
The signal path is
ARINC 717 Low
open
FDR Data Input
The signal path is
ARINC 717 Low
shorted
FDR Data Output
The signal path is
ARINC 717 Low
open
Local Effect
Loss of ability to record
ARINC 429 Low signal
data
Loss of ability to record
ARINC 429 High signal
data
Loss of ability to record
ARINC 429 High signal
data
Only 64, 128 or 1024
Wps rates available
Only 256 or 512 Wps
rates available
Only 64, 256 or 1024
Wps rates are available
Only 128 and 512 Wps
rates are available
No Effect
No Effect
Loss of ability to record
ARINC 429 Low signal
data
Loss of ability to record
ARINC 429 Low signal
data
Loss of ability to ac­
quire coherent FDR
Data Input (ARINC 717
Low)
Loss of ability to ac­
quire coherent FDR
Data Input (ARINC 717
Low)
Disrupted FDR Data
Output (ARINC 717
Low) echoed back to
FDAU
23–70−40
FDR Function Testing & Fault Isolation
Rev. 03 Page 219
Rev.04 Page 219
End Effect
Unable to record
ARINC 429 Low signal
data
Unable to record
ARINC 429 High signal
data
Unable to record
ARINC 429 High signal
data
The Main Processor
may generate an FDR
fault depending upon
the rate
The Main Processor
may generate an FDR
fault depending upon
the rate
The Main Processor
may generate an FDR
fault depending upon
the rate
The Main Processor
may generate an FDR
fault depending upon
the rate
No Effect
No Effect
Unable to record
ARINC 429 Low signal
data
Unable to record
ARINC 429 Low signal
data
Unable to record good
ARINC 717 data input
from the Main Pro­
cessor
Unable to record good
ARINC 717 data input
from the Main Pro­
cessor
Disrupted FDR Data
Output (ARINC 717
Low) echoed back to
FDAU
Feb. 27/13
Mar. 21/14