L3 FA5000 Component Maintenance Manual With Illustrated Parts List page 120

Cockpit voice and data recorder
Hide thumbs Also See for FA5000:
Table of Contents

Advertisement

Table 205. Main Processor Troubleshooting Chart (Continued)
Item
Function Type
ID
Watch Dog Timer;
ARINC 429 RX/TX; Dis-
crete I/Ps and O/Ps;
FDR Data; Frequency
Counter; CSMU Inter-
face; Power Supply
Status
A003
Watch Dog Timer;
ARINC 429 RX/TX; Dis-
CSMU
crete I/Ps and O/Ps;
Inter-
FDR Data; Frequency
face
Counter; CSMU Inter-
face; Power Supply
Status; ARINC 717;
RS422
Watch Dog Timer;
ARINC 429 RX/TX; Dis-
crete I/Ps and O/Ps;
FDR Data; Frequency
Counter; CSMU Inter-
face; Power Supply
Status; ARINC 717;
RS422
Watch Dog Timer;
ARINC 429 RX/TX; Dis-
crete I/Ps and O/Ps;
FDR Data; Frequency
Counter; CSMU Inter-
face; Power Supply
Status; ARINC 717;
RS422
A004
Non−Volatile Memory:
Configuration and Error
Memor
Log
y
SEER
OM
Use or disclosure of information on this sheet is subject to
The document reference is online, please check the correspondence between the online documentation and the printed version.
the restrictions on the cover page of this document.
AVIATION RECORDERS
COMPONENT MAINTENANCE MANUAL
Model FA5000
Failure
Local Effect
Mode
Single Event
The FPGA ini-
Upset (SEU)
tially does not
operate: It is in
an undeter-
mined condi-
tion
Over/Under
The CSMU In-
Voltage
terface fails:
The DSP and
FPGA internal
resources/re-
gisters are un-
able to com-
municate with
the CSMU
Incorrect O/P
The CSMU In-
terface fails:
The DSP and
FPGA internal
resources/re-
gisters are un-
able to com-
municate with
the CSMU
Single Event
The CSMU ini-
Upset (SEU)
tially does not
operate
Loss of
The SEEP-
Power
ROM fails: Un-
able to stores
errors, identify
location, part
number, MAC
Address, or
perform Time
Sharing
Next Effect
End Effect
The MP PWA
The CVDR initially does not oper-
initially does
ate: some data may be corrupt,
not operate
lost and/or may not be recorded,
stored or copied NOTE: The cor-
rupted FPGA data is erased and
replaced
The MP PWA
The CVDR fails to operate
fails to operate
The MP PWA
The CVDR fails to operate
fails to operate
The MP PWA
The CVDR initially does not
initially does
operate: some data may be
not operate
corrupt, lost and/or may not be
recorded, stored or copied
NOTE: The DSP and the
FPGA's internal resources/re-
gisters reset and communica-
tion is re−restablished with the
CSMU
The MP PWA
The CVDR PWA fails to oper-
fails to operate
ate
23–70−40
FDR Function Testing & Fault Isolation
Rev. 03 Page 224
Rev.04 Page 224
Feb. 27/13
Mar. 21/14

Advertisement

Table of Contents
loading

This manual is also suitable for:

500-4030-000 rips

Table of Contents