10.3 IECEx

WARNING
• Only trained persons use this instrument in
industrial locations.
• A modification of the equipment would
no longer comply with the construction
described in the certificate documentation.
(1) Technical Data
• Flameproof
Applicable Standard : IEC 60079-0:2011
IEC 60079-1:2014
Certificate : IECEx DEK 11.0077X
Type of Protection:
Ex db IIC T6...T1 Gb (Integral Type and Remote
Type Detector)
Ex db IIC T6 Gb (Remote Type Convertor)
Specification of Protection:
Temperature Class: (Integral Type and Remote
Type Detector)
Temperature Class
T6
T5
T4
T3
T2
T1
*1 Note: Use /HT version above +250°C
Temperature Class: T6 (Remote Type Convertor)
Ambient Temperature:
–30 to +60°C (With indicator)
–40 to +60°C (Without indicator)
Power Supply: 9 to 32Vdc max.
Specific conditions of use
• Electrostatic charges on the non-metallic parts
(excluding glass parts) or coated parts of the
equipment shall be avoided.
• The flameproof joints differ from the standard
values in IEC 60079-1. Only personnel authorized
by the manufacturer of the equipment can repair
the flameproof joints.
• The property class of the fasteners used to
fasten the sensor assembly part the transmitter
enclosure is at least A2-50.
<10. EXPLOSION PROTECTED TYPE INSTRUMENT>
Process Temperature
-40°C to +80°C
-40°C to +100°C
-40°C to +135°C
-40°C to +200°C
-40°C to +300°C
-40°C to +450°C
• Intrinsically Safe
Applicable Standard: IEC 60079-0:2011
IEC 60079-11:2011
Certificate: IECEx DEK 15.0012X
Type of Protection:
Ex ia IIC T4...T1 Ga (Integral Type)
Ex ia IIC T6...T1 Ga (Remote Type Detector)
Ex ia IIC T4 Ga (Remote Type Converter)
Ambient Temperature:
-40 to +60°C (Integral Type)
-50 to +80[+78]°C (Remote Type Detector)
-40 to +80°C (Remote Type Converter)
(Option /LT below -29°C, [ ] for Option /MV at T6)
Connect sensor circuit of DYA and DY-N (/HT)
Electrical Data:
Entity Ui = 24 V, Ii = 250 mA, Pi = 1.2 W,
Ci = 3.52 nF, Li = 0 mH
FISCO (IIC) Ui = 17.5 V, Ii = 500 mA, Pi = 5.5 W,
Ci = 3.52 nF, Li = 0 mH
Temperature Class:
(Integral Type)
Temperature Class
T4
T3
T2
T1
(Remote Type Detector)
Temperature Class
T6
T5
T4
T3
T2
T1
*: Use /HT option above +250 °C, use /LT option below -29 °C, [ ]
for /MV option.
Electrical Connection: ANSI 1/2 NPT female,
ISO M20 X 1.5 female
Specific conditions of use
• Electrostatic charges on the non-metallic parts
(excluding glass parts) or coated parts of the
equipment shall be avoided.
• When the enclosure of the flow meter or the
flow converter are made of aluminum, if it is
mounted in an area where the use of EPL Ga
equipment is required, it must be installed such
that, even in the event of rare incidents, ignition
sources due to impact and friction sparks are
excluded.
• The dielectric strength of at least 500 V a.c.
r.m.s. between the intrinsically safe circuits and
the enclosure of the flow meter or the converter
is limited only by the overvoltage protection.
10-9
Process Temperature
≤ +135°C
≤ +200°C
≤ +250°C
≤ +250°C
Process Temperature*
≤ +84/[+78]°C
≤ +100°C
≤ +135
°C
≤ +199
°C
≤ +299/[+288]°C
≤ +449/[+438]°C
IM 01F06F00-01EN