The PowerView® VVB motor is suited to be used with Vertical blind hardware from HunterDouglas.
1. Delivery condition
As standard, no remote control or hub is connected to the motor. No limits are set. Motor is default set to a
motor type. If the motor condition is unknown, perform the following steps.
Vertical blind
IMPORTANT
The motor type (default set to
Split stack Vertical blind
Use the
PowerView® Programmer
Note
The PowerView® Vertical blind motor can only be installed to the back of the headrail and not on top!
1.1. Check motor type
The motor can be programmed as a
Left stack Vertical blind
Right stack Vertical blind
Split stack Vertical blind
By reading out the LED sequence after power up, the motor type can be seen.
Page 1 of 24
Vertical Venetian blind
Left stack Vertical blind
type, depending on your wishes.
software tool to change.
(default)
), might be changed to a
Right stack Vertical blind
Left stack
or
version: 1.1

Advertisement

loading

Summary of Contents for HunterDouglas PowerView

  • Page 1 PowerView® Programmer software tool to change.  Note The PowerView® Vertical blind motor can only be installed to the back of the headrail and not on top! 1.1. Check motor type The motor can be programmed as a • (default) Left stack Vertical blind •...
  • Page 2 MANUAL Left stack Right stack Split stack 1.1.1 Power up the motor by connecting the power cable to the battery wand or power supply. 1.1.2 Immediately Check the motor button LED sequence after start up. The LED sequence should read: Left stack blind type Right stack blind...
  • Page 3 Note This procedure can be skipped for a fresh out of the box motor. The motor will jog 2x when receiving any PowerView® command (e.g. Pressing the manual control button on the motor), to confirm no limits are set. 1.2.1...
  • Page 4: Network Reset

    This procedure will erase all network data stored in the motor, including Network ID and Group assignments. It will not clear the end limits. Completing a Network reset will prevent a PowerView® remote or App from operating the window covering until it is reprogrammed.
  • Page 5 The Network ID and Group assignments have been cleared. 2. Pairing a remote A PowerView® remote can control up to 6 individual groups of blinds (buttons 1 to 6 at the top of the remote). The instructions below assign a blind to group 1. Locate the on your blind.
  • Page 6 MANUAL Press the  button. group1  IMPORTANT Watch out to perform steps 2.4 and 2.5 within 3 seconds! Press and hold the manual control button Press the  button. open The blind will jog 1x Release the manual control button Page 6 of 24 version: 1.1...
  • Page 7 MANUAL Press and hold the  button for 6 seconds. stop The remote will exit programming mode automatically after 20 seconds. Keep pressing until the remote lights stop blinking 3. Checking motor direction  IMPORTANT Reversing motor direction is only possible with a fresh out of the box motor (no limits set) or when the end limits are reset.
  • Page 8 MANUAL 3.1.2 Press the  button. open Make sure  group1 on the remote is selected. The blind will jog 1x 3.1.3 Release the manual control button The motor LED turns red to acknowledge the motor is in program mode 3.2.
  • Page 9 MANUAL 3.2.2.A If the blind moves to the open position, it will 3.2.2.B If the blind moves to the close position, hit the mechanical end limit and stop Press the  stop button and continue with step 4.1.4 Motor direction NOT OK! Motor direction OK! 3.2.3 Press and hold the...
  • Page 10: Open Limit

    MANUAL 4.1. Open limit 4.1.1 Press and hold the manual control button 4.1.2 Press the  button. open Make sure  group1 on the remote is selected. The blind will jog 1x 4.1.3 Release the manual control button The motor LED turns red to acknowledge the motor is in program mode 4.1.4 Use the ...
  • Page 11 MANUAL 4.1.5 Use the  button to let the blind hit the open mechanical end limit. The motor will stop moving. The motor needs to hit the headrail! 4.1.6 Press and hold the  stop button for 6 seconds. DO NOT select a group on the remote! Keep pressing until the remote lights start blinking ...
  • Page 12 MANUAL 4.1.8 Press the  button. open The blind will jog 1x to acknowledge the limit is set 4.1.9 Release the manual control button The motor LED turns off 4.1.10 Press and hold the  button for 6 seconds. stop The remote will exit programming mode automatically after 20 seconds.
  • Page 13: Close Limit

    MANUAL  Note To re-position the open limit of the blind, repeat step 4.1 Open limit 4.2. Close limit 4.2.1 Press and hold the manual control button 4.2.2 Press the  close button. Make sure  on the remote is selected. group1 The blind will jog 1x 4.2.3...
  • Page 14 MANUAL 4.2.4 Use the  ,  and  buttons to open stop close move the blind to the desired close position. DO NOT let de blind hit the mechanical limit. Stop the blind at its end position! 4.2.5 Press and hold the  stop button for 6 seconds.
  • Page 15 MANUAL 4.2.7 Press the  button. close The blind will jog 1x to acknowledge the limit is set 4.2.8 Release the manual control button The motor LED turns off 4.2.9 Press and hold the  stop button for 6 seconds. The remote will exit programming mode automatically after 20 seconds.
  • Page 16 To re-position the close limit of the blind, repeat step 4.2. Close limit 5. Slat open position The slat open position is automatically set, by selecting blind type in the PowerView® Programmer software tool: • (default) Left stack Vertical blind •...
  • Page 17 MANUAL Press the  button. group1 Press the  close button to move the blind to the close position.  IMPORTANT Watch out to perform steps 5.4 and 5.5 within 3 seconds! Press and hold the on your manual control button blind.
  • Page 18 MANUAL Press and hold the  button until the arrow up motor LED turns red. the motor LED turns red to acknowledge the motor is in program mode Determine the maximum rotation position using the  ,  and  buttons.
  • Page 19 MANUAL Press and hold the  button for 6 seconds. stop DO NOT select a group on the remote! Keep pressing until the remote lights start blinking  IMPORTANT Watch out to perform steps 5.8 and 5.9 within 3 seconds! Press and hold the on your manual control button...
  • Page 20 MANUAL 5.10 Release the manual control button The motor LED turns off 5.11 Press and hold the  button for 6 seconds. stop The remote will exit programming mode automatically after 20 seconds. Keep pressing until the remote lights stop blinking 5.12 The slat open position is set!
  • Page 21 MANUAL Blind type: Left stack Vertical blind Blind type: Right stack Vertical blind Blind type: Split stack Vertical blind After Reset End limits reset (factory default), see chapter Network reset on manual control button release, chapter 1.3. Blind type: Left stack Vertical blind Network reset on manual control button...
  • Page 22 MANUAL Ultra low battery indication (< 8.5V). The blind will not run anymore. Change the batteries. Others The maximum motor current has been reached. E.g. The blind is stuck at an obstacle. Steady red LED. The motor is in program (Continuous) mode (during limit setting).
  • Page 23 MANUAL Jog 3x Action denied on open limit set: open limit is not referenced (did not hit headrail! See step 4.1.5) Jog 4x Action denied on limit set: invalid product height Page 23 of 24 version: 1.1...
  • Page 24: Important Notice

    MANUAL Important notice Hunter Douglas Europe B.V. and its affiliates (Hunter Douglas) reserve the right to make corrections, enhancements, improvements and other changes to its products and services, and to discontinue any product or service. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete.