Remote Start; Status Output; Finishing Installation - Harvia sentiotec Pro C2 Instructions For Installation And Use Manual

Sauna control unit
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 50
Installation instructions, only for experts

5.10. Remote start

This is connected using terminals "S", "B" and "C". "S" stands for sauna mode.
"B" is a +24 V DC output. This must be activated using a switch or an actuator
on terminal "S".

5.11. Status output

Any electrical device can be connected to the status output terminal which is
suitable for 24 V DC voltage and draws a current no greater than 200 mA.
Make sure the polarity is correct when connecting a device. When LEDs are
used, a suitable series resistor must be used.

5.12. Finishing installation

1. Connect the earth conductor for the power supply cable and all devices to
the earth rail g.
2. Place the cover of the housing on the upper edge of the junction box.
3. Push the clip locks inwards lightly, and turn the cover of the housing down-
wards until it engages audibly.
p. 20/48