Summary of Contents for SICK DUSTHUNTER C200
Page 1
Title Page MMMOPERATING INSTRUCTIONS MMMI O P E R A T I N G I N S T R U C T I O N S DUSTHUNTER C200 Dust Concentration Monitor Installation, Operation, Maintenance...
Page 2
Original document This document is an original document of SICK AG. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08 | SICK Subject to change without notice...
Device configuration ..................31 SOPAS ET (PC program) ................32 8011952/YWL2/3-0/2016-08 | SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Page 4
Adjusting the laser beam for scattered light measurement..63 4.2.5 Entering application-specific parameters ........64 O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08 | SICK Subject to change without notice...
Page 5
Optional external purge air unit ..........102 Shutdown....................103 8011952/YWL2/3-0/2016-08 | SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Page 6
MCU with integrated purge air supply ........123 7.5.3 Optional external purge air unit ..........123 O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08 | SICK Subject to change without notice...
Do not point the laser beam at persons ▸ Pay attention to laser beam reflections. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
The DUSTHUNTER C200 measuring system is not approved for use in potentially ● explosive atmospheres. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
The specified maintenance and inspection tasks are carried out regularly by qualified, experienced personnel. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Page 10
Ensure the device can be switched off with a power isolating switch/circuit breaker in accor- dance with EN 61010-1. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
(O), relative opacity (ROPA), extinction (E) and dust concentration (c) are derived from this variable. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Measured value with response time Process change Response time t in s 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Changes to the interval time are first effective after the next start timepoint. ● O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
Page 15
“Warning” is set fixed to 3% and the value for “Failure” to 4%. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Page 16
Control reflector (only on the sender side) Pivoted shutter O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
As standard, each sender/receiver unit is connected to an MCU control unit via the connection line. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Optics, electronics and mechanical components can then be easily accessed for maintenance work. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
Page 19
Retaining bracket Tension spring Bevel gear 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Knurled screw Purge air connection Flange O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Page 21
Light trap for scattered light measurement Hinge Connection for sender unit 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Securing bolt Material St 37 or 1.4571 O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
● Transmission ● Relative opacity ● Resolution 10 bits 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Processor board Display module (option) Interface module (option) O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Page 25
8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
- N: Without EX certification Software - E: Emission measurement O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Menu Display of main menu and selection of submenus 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Page 28
– The MCU and the MCU remote control unit are interlocked (it is not possible to operate both MCUs at the same time). O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
A weatherproof cover is available for use outdoors (see “Weatherproof covers”, page 121). 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
The zero tube is closed off with end flaps when not in use so that no dust can penetrate the tube. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
Optional external purge air unit + adapter 40-25 > +2 hPa MCU-N (on sender/receiver unit) 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
SOPAS ET is delivered on the product CD. Alternatively, you can download SOPAS ET free of charge from the SICK homepage (“Downloads”). O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
Plan adequate line cross-sections and supply requirements “Technical Data”, page 111) fuses 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Flange with tube Reflector/scattered light receiver Tube O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Leave enough clearance around the flange with tube to fit the sender/receiver unit and reflector. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Page 36
± 1°. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200...
Page 37
Close off the flange opening after fitting to prevent gas escaping. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
(see “MCU control unit”, page > 350 > 540 O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Page 39
10 m away from the MCU control unit. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
“Purge air unit layout and assembly dimensions (dimen- sions in mm)”, page 41). O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Steel pipe 50 x 5 DIN 2391 Duct 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Insert the holding catches into the counterpieces from the side, twist and lock in. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
The person setting the system up is responsible for the safety of the system in which the device is integrated. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Purge air outlet DN 40 for reflector/scattered light receiver DHC-R1 O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Purge air hose Adapter 40 - 25 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Page 46
Fuse each phase separately. Use circuit breakers to prevent phase failures on one side. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
Only modify wiring when disconnected from the power supply and potential- free. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Connections for analog inputs 1 and 2 O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
To open, connect the plug connector to the plug page 44, §3.3.2 on the sender/receiver unit. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Socket Plug -24 V +24 V SICK line Socket O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
122) to the sender/receiver unit and reflector/ scattered light receiver and screw tight. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Module carrier AI 2 + - AI 1 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
76) before being used for continuous measurement of dust content. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
1 Disconnect the DUSTHUNTER from your laptop/PC. 2 Input: devmgmt.msc 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Page 56
A new COM port is shown. Use this COM port for communication. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
12 Assign a name for this search 13 “Finish” 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
– Onsite installation of a “zero tube”. The tube must fit on the flange tubes and have little reflection inside. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
Page 59
Wait approx. 30 min before starting the following work (measuring system must have reached operating temperature). 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Fig. 37: Cover screw for focussing opening O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Page 61
(2) on the back of the enclosure (3). 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Page 62
NOTE: The measuring system must be scaled again after every focus change. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Light trap ▸ Put the cover back on. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Entering application-specific parameters Fig. 41: SOPAS ET menu: DH C200/Configuration/Application parameter (example) O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Page 65
After deactivation of the EPA conformity, limit contamination and limit warning are reset to standard values (40% or 30%). 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Cup springs (4 pairs); only with fastening set for sender/receiver unit Horizontal alignment Fixing point Vertical alignment O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Page 67
“Aligning the laser beam to the light trap”, page 63 when this is not the case. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
The sender/receiver unit must be connected to the MCU. Fig. 45: SOPAS ET menu: MCU/Configuration/Application selection O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
55), the Level 1 password set and the “Maintenance” mode set. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
(see “Function check output on a plotter”, page 14). O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
“Maintenance” state current value ≠ LZ 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Page 72
Upper measuring Physical value at 20 mA range limit O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Page 73
Scaling” in the same manner as for “Analog Output Parameter 1” and “Analog Output 1 Scaling”. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
This parameter opens the “Analog input 4 - Oxygen” field to set the lower and upper range limit values and the Live Zero value. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
Sensor 1 time”, page Setting range 1 ... 600 s 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
On the LC-Display (option), the dust concentration is shown in mg/m³ as uncalibrated value. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
Page 77
This method allows changing the parameters for the selected measuring range as desired. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
(value entered for 20 mA; normally 2.5 x fixed limit value) O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Page 79
This method allows changing the parameters for the selected measuring range as desired. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Parameter protocol example Fig. 50: DUSTHUNTER C200 Parameter protocol (example) O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Fig. 51: SOPAS ET menu: MCU/Maintenance/Maintenance Standard start-up is now completed. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
GSD file and measured value assignment are available for the Profibus DP module on request. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
“Reset module”. Fig. 53: SOPAS ET menu: MCU/Configuration/IO configuration/Interface Module 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Select the desired value using the “^” and/or “→” buttons and write it to the device with “Save” (confirm 2x). 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Page 86
Set the MCU to “Maintenance” mode, select the “MCU Variant” submenu and select the type “DUSTHUNTER C”. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
Page 87
Enter the default password and store the type with “Save” (confirm twice). The other selection options have no significance here. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
76) using the “^” and/or “→” buttons and write to the device with “Save” (confirm twice). O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
Page 89
START-UP AND PARAMETER SETTINGS Fig. 57: Entering the regression coefficients 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Display Settings” directory. Fig. 58: SOPAS ET menu: MCU/Configuration/Display Settings O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Page 91
Concentration s.c. (SI) MCU Value 2 Concentration s.c. (ext) 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
“Measurement” after the operating volt- age is switched on again. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
Page 93
● Replacement air filter, preliminary filter (for suction) ● 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Carefully clean glass pane (5) (both sides), zero point reflector (2) and sender optics (4) with an optics cloth. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
Page 95
Connect with the DH C200 device file, select the “Diagnosis / Check values” directory and check the contamination value. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Page 96
(see “SOPAS ET menu: DH C200/Adjustment/Manual Adjustment/Motor control”, page 94). ▸ Resume Measuring mode. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Scattered light receiver for long active measuring paths 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Lay the toothed belt on the drive axis, push pivoted shutter back onto the axis and reinstall the tension spring. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
Page 99
Manual Adjustment/Motor control”, page 94). ▸ Resume Measuring mode. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
The purge air supply does not have to be switched off to clean the filter housing or to replace the filter element, i.e. the components can remain on the duct. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
Strap retainer Filter housing Filter housing cover 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Reconnect the purge air hose to the filter outlet using the hose clamp. ▸ Switch the fan on again. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Secure purge air hoses against penetration by dirt and moisture. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
See the Service Manual for a detailed description of messages and options for clear- ance. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
● Malfunctions listed below can probably be cleared onsite. 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Page 106
(core cross-section too low in relation to the line length) O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Description of error or warning: In the description field of SOPAS ET ● 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Page 108
MCU in “Test” mode. Deactivate “System Test” mode (“Maintenance” directory) O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Fig. 72: Replacing the fuse Fuse holder Fuse 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
4): With swivel angle ± 0.3 °; total swivel range ±1 ° 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
These have been determined based on SICK's many years of experience and are valid assuming constant particle size and characteristics. O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
Page 113
4000 3000 2000 1000 Active measuring path in m 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
∅ 25 Part No. Designation Sender/receiver unit DHC-T 1044863 O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
∅ 25 Designation Part No. 1044864 Reflector/scattered light receiver DHC-R0 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Page 116
∅ 40 Part No. Designation 1044865 Reflector/scattered light receiver DHC-R1 O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Flange with tube, Di = 152 Length 350 mm, 1.4571 2045420 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
MCU remote control unit with power supply unit 2075568 O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Page 119
Supply voltage 24 V DC, with purge air unit, with display 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Purge air unit with blower 2BH13 and purge air hose, length 10 m 1012409 O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK...
2702407 DHC-T, DHC-R0 2048567 Weatherproof cover flange k225 DHC-R1 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Part No. Check filter set 2048676 2042907 Adjusting stand O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08| SICK Subject to change without notice...
Filter element Micro-Topelement C11 100 5306091 4003353 Optics cloth 8011952/YWL2/3-0/2016-08| SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Page 124
Product description ................11 Purge air unit ..................29 O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 8011952/YWL2/3-0/2016-08 | SICK Subject to change without notice...
Page 125
INDEX 8011952/YWL2/3-0/2016-08 | SICK O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER C200 Subject to change without notice...
Page 126
E-Mail sales@sick.co.nz United Arab Emirates China Norway E-Mail sick@sick.no USA/Mexico Denmark Poland E-Mail sick@sick.dk Finland Romania Vietnam France Russia Gemany Singapore Great Britain Slovakia E-Mail mail@sick-sk.sk Hong Kong Slovenia Hungary South Africa www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...