Festo MPA-C Series Manual page 52

Valve terminal with mpa-c pneumatics
Table of Contents

Advertisement

6
Modification and maintenance
1
8
7
1
Sealing disc
2
Mounting screws of the cover
3
Cover of the manifold sub-base
4
Valve
Fig. 6.2
Mounting of valve or cover
4. Put the valve or cover plate into the manifold sub-base.
5. Screw the valve or cover plate at first only lightly and then tighten it (tightening torque: 0.65 Nm
(±10 %)).
6. Put the IP seal and the cover onto the manifold sub-base in the right position.
7. Screw the cover at first only lightly and then tighten it (tightening torque: 2.0 Nm (±10 %)).
52
2
5
Cord seal
6
Manifold sub-base
7
IP seal
8
Mounting screws of the valve
Festo – GDCV-MPAC-EN – 1407NH – English