shrink tubing or tape to this connection. The power plug is designed to disconnect
during a frangible event.
Apply Loctite 8023 marine grade anti-seize to the exposed anchor stud threads.
f.
Place one ½" two-piece lock washer and one ½" flange nut onto each anchor stud.
g.
Tighten the flange nuts finger tight.
h.
Follow the instructions of Section 9.9 to finish raising the sign.
i.

9.8.3 Signs with External Power Cable Installation Method 1

Lower the sign with the legs and flanges into place on the anchor studs, see Figure 38,
a.
pg. 64. Do not yet install the ½" flange nuts.
Plug the external sign power cord into the series isolation transformer secondary
b.
receptacle protruding through the base plate. Note, Do not apply heat shrink tubing or
tape to this connection. The power plug is designed to disconnect during a frangible
event.
Apply Loctite 8023 marine grade anti-seize to the exposed anchor stud threads.
c.
Place one ½" two-piece lock washer and one ½" flange nut onto each anchor stud.
d.
Tighten the flange nuts finger tight.
e.
Follow the instructions of Section 9.9 to finish raising the sign.
f.
Instruction Manual
AGS-LED
312 LED Series
300mm and 400mm
8
DOCUMENT 1218
REV. B