MULTICAL® 603
11.4 Mounting of antenna
The wireless M‐Bus modules must be connected to an internal or an external antenna.
When mounting an external antenna, you must make sure that the antenna cable is arranged as shown below
to prevent it from being damaged when the calculator is assembled. Before exchanging or mounting modules,
the supply to the meter must be disconnected. The same applies to the mounting of an antenna.
11.5 Retrofitting modules
Modules for MULTICAL
ready for installation. However, some modules require final individual configuration, which can be carried out by
means of the PC program METERTOOL HCW (read more about METERTOOL HCW in the technical Description 5512‐
2096). Before exchanging or mounting modules, the supply to the meter must be disconnected. The same applies to
the mounting of an antenna.
Type
Module
No.
10
Data + 2 pulse inputs (In‐A, In‐B)
11
Data + 2 pulse outputs (Out‐C, Out‐D)
20
M‐Bus + 2 pulse inputs (In‐A, In‐B)
21
M‐Bus + 2 pulse outputs (Out‐C, Out‐D)
144
Wireless M‐Bus module with internal
603 are also supplied separately for retrofitting. The modules are factory‐configured and
Possible configuration after installation
Pulse figure and pre‐setting of In‐A and In‐B can be
changed via METERTOOL HCW.
Pulse duration of Out‐C and Out‐D is changed via
METERTOOL HCW.
Pulse figure and preset of In‐A and In‐B can be changed
via METERTOOL HCW.
Primary and secondary M‐Bus addresses can be changed
via METERTOOL or M‐Bus. The register contents of the M‐
Bus data package can be changed via METERTOOL HCW
and READY Manager.
Pulse duration of Out‐C and Out‐D is changed via
METERTOOL HCW.
Primary and secondary M‐Bus addresses can be changed
via METERTOOL or M‐Bus. The register contents of the M‐
Bus data package can be changed via METERTOOL HCW
and READY Manager.
Kamstrup A/S ∙ Technical description ∙ 5512‐2029_A1_GB_06.2017