Rack Mounting Instructions
Review the documentation that comes with your rack cabinet for safety and cabling information. When
installing your storage server in a rack, consider the following:
Ensure the room air temperature is below 35°C (95°F).
Do not block any air vents, usually 15 cm (6 in.) of air space provides proper airflow.
Plan the device installation starting from the bottom of the rack.
Install the heaviest device in the bottom of the rack.
Do not extend more than one device out of the rack at the same time.
Remove the rack doors and side panels to provide easier access during installation.
Connect all power cords to properly wired and grounded electrical outlets.
Take precaution to prevent overloading the power outlets when you install multiple devices in a rack.
Use safe practices when lifting.
You will need a flat-blade and a Phillips screwdriver during the installation. The following is a list of items
that come with your option. If any items are missing or damaged, contact your place of purchase.
Cage nuts (10)
Clip nuts (10)
M6 screws (10)
Side rails (2)
Note: Refer to your storage server documentation for handling guidelines before removing any
ESD-sensitive devices. The first four steps of the installation procedure involve removing some
components from the storage server in order to reduce the weight of the storage server for easier
installation.
18 kg (37 lbs)
32 kg (70.5 lbs)
Appendix B. Rack mounting template and instructions
55 kg (121.2 lbs)
73