Chapter 4. Operating the storage server

This chapter describes the tasks that are required to operate the storage server.

Turning the storage server on and off

This section contains instructions for turning the storage server on and off under
normal and emergency situations.
If you are turning on the storage server after an emergency shutdown or power
outage, refer to "Restoring power after an emergency shutdown" on page 28.

Turning on the storage server

Use this procedure to turn on the power for the initial startup of the storage server.
1. Verify that:
2. Check the system documentation for the hardware devices that you intend to
3. Turn on the power to each device, based on the power-on sequence in step 2. To
4. Use the storage-management software and the Fault LEDs to check the overall

Turning off the storage server

Attention: Except in an emergency, never turn off the power if any storage server
Fault LEDs are on. Correct the fault before you turn off the power, using the proper
troubleshooting or servicing procedure. This ensures that the storage server will
power up correctly later. For more information, see "Troubleshooting" on page 65.
© Copyright IBM Corp. 2000
a. All communication and power cables are plugged into the back of the storage
server and a properly grounded ac electrical outlet
b. All hard disk drives are locked securely in place. For more information, see
"Installing hot-swap drives" on page 38.
Attention: If you are restarting the system after a normal shutdown, wait at least
10 seconds before you turn on the power using the power-on sequence in step 2.
power up, and then determine the proper startup sequence. Use the following
power-on sequence, where applicable:
a. Turn on the power to the supporting devices (for example, Ethernet switches,
managed hubs, and management stations) before the storage server.
b. You must turn on the expansion units before the storage server. The
controllers might not recognize the correct configuration if the drives are
powered up after the storage server. For instructions on powering up the
expansion units, refer to the expansion-unit documentation.
c. Turn on the power to the storage server; then, restart or turn on the power to
the host.
turn on power to the storage server, turn on the power-supply switches on the
back of the storage server. You must turn on both power-supply switches to take
advantage of the redundant power supplies.
status of the storage server and its components. All LEDs should be green on the
front of the storage server. If they are not, use the storage-management software
to diagnose the problem (see "Monitoring status through software" on page 28).
Note: The green Drive active LED and amber Drive fault LED below the drive
CRUs might flash intermittently as the drives spin-up. Wait until the storage
server is finished powering up before checking the LEDs on the front of the
storage server. For more information, see "Checking the LEDs" on page
29.