ADF Web HD67B77-A1 User Manual

ADF Web HD67B77-A1 User Manual

Profinet master / snmp agent - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.000
English
PROFINET Master / SNMP Agent -
Converter
(Order Code: HD67B77-A1)
for Website information:
http://www.adfweb.com/?Product=HD67B77
for Price information:
http://www.adfweb.com/?Price=HD67B77-A1
Benefits and Main Features:
Triple electrical isolation
Two Ethernet ports
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
User Manual PROFINET Master / SNMP Agent
Document code: MN67B77_ENG
For others PROFINET Master devices, see also the following links:
PROFINET Master from/to ...
www.adfweb.com?Product=HD67B45
www.adfweb.com?Product=HD67B70
www.adfweb.com?Product=HD67B71
www.adfweb.com?Product=HD67B72
www.adfweb.com?Product=HD67B73
www.adfweb.com?Product=HD67B74
www.adfweb.com?Product=HD67B75
www.adfweb.com?Product=HD67B76
www.adfweb.com?Product=HD67B78
www.adfweb.com?Product=HD67B79
www.adfweb.com?Product=HD67B80
www.adfweb.com?Product=HD67B81
www.adfweb.com?Product=HD67B82
www.adfweb.com?Product=HD67B84
Do you have an your customer protocol?
See the following links:
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
Revision 1.000
Page 1 of 27
(OPC UA server)
(Serial)
(Modbus Slave)
(PROFIBUS Slave)
(CAN)
(CANopen)
(DeviceNet Slave)
(Modbus TCP slave)
(EtherNet/IP Slave)
(KNX)
(MQTT)
(BACnet slave)
(IEC 61850 server)
(Ethernet)
Phone +39.0438.30.91.31

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67B77-A1 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web HD67B77-A1

  • Page 1 Industrial Electronic Devices User Manual Revision 1.000 English PROFINET Master / SNMP Agent - Converter (Order Code: HD67B77-A1) for Website information: http://www.adfweb.com/?Product=HD67B77 for Price information: For others PROFINET Master devices, see also the following links: http://www.adfweb.com/?Price=HD67B77-A1 PROFINET Master from/to …...
  • Page 2: Table Of Contents

    User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 2 of 27 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Page Dear customer, we thank you for your attention and we remind you that you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 3 of 27 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 4 of 27 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 5 of 27 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67B77-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6: Characteristics

    Page 6 of 27 Industrial Electronic Devices CHARACTERISTICS: The HD67B77-A1 is a PROFINET Master / SNMP Agent converter. It allows the following characteristics: Up to 4096 bytes in reading and 4096 bytes in writing; Two-directional information between SNMP and PROFINET;...
  • Page 7: Power Supply

    POWER SUPPLY: The devices can be powered between a wide range of tensions. For more details see the two tables below. Vmin Vmax Vmin Vmax HD67B77-A1 Consumption at 24V DC: Device W/VA HD67B77-A1 Caution: Not reverse the polarity power HD67B77-A1 ADFweb.com Srl –...
  • Page 8: Function Modes

    User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 8 of 27 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the Dip1 of ‘Dip-Switch A’: The first, with Dip1 in Off position (factory setting), is used for the normal working of the device. The second, with Dip1 in On position, is used for upload the Project/Firmware.
  • Page 9: Leds

    User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 9 of 27 Industrial Electronic Devices LEDS: The device has got six LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode ON: Device powered...
  • Page 10: Ethernet

    ETHERNET: The Ethernet connection must be made using Connector3 or Connector4 of HD67B77-A1 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps. To connect the device to an Hub/Switch is recommended the use of a straight cable, to connect the device to a PC/PLC/other is recommended the use of a cross cable.
  • Page 11: Use Of Compositor Sw67B77

    User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 11 of 27 Industrial Electronic Devices USE OF COMPOSITOR SW67B77: To configure the Converter, use the available software that runs with Windows called SW67B77. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 12: New Project / Open Project

    User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 12 of 27 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “PROFINET Master / SNMP Agent - Converter”...
  • Page 13: Software Options

    User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 13 of 27 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 14 User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 14 of 27 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 15: Set Communication

    User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 15 of 27 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, PROFINET and SNMP. By Pressing the “Set Communication” button from the main window for SW67B77 (Fig.
  • Page 16 User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 16 of 27 Industrial Electronic Devices The means of the fields for “SNMP Agent” are: In the field “IP ADDRESS” the IP address of SNMP side of the converter is defined; In the field “SUBNET Mask”...
  • Page 17: Profinet Access

    User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 17 of 27 Industrial Electronic Devices PROFINET ACCESS: By Pressing the “PROFINET Access” button from the main window for SW67B77 (Fig. 2) the window “Definition of PROFINET Devices Present in Network”...
  • Page 18 User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 18 of 27 Industrial Electronic Devices The means of the fields below are: If the field “Name of Station” is checked, the name of the PROFINET slave is defined; In the field “IP Address”...
  • Page 19 User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 19 of 27 Industrial Electronic Devices By clicking on “Modules” button, it is possible to import the modules for the selected PROFINET slave device. The window “Definition Module and/or Submodules of PROFINET Device”...
  • Page 20: Set Snmp Access

    User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 20 of 27 Industrial Electronic Devices SET SNMP ACCESS: By pressing the “Set SNMP Access” button from the main window for SW67B77 (Fig. 2) the “Set SNMP Access” window appears (Fig. 6). In this section, it is possible to create the OIDs for SNMP side to read or write using GET and SET commands or to be sent as TRAP messages.
  • Page 21: Mib File

    User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 21 of 27 Industrial Electronic Devices The data of the columns in the “SNMP Write” have the following meanings: field “Enable” checked, the SNMP OID is enabled; field “Community Name”...
  • Page 22: Update Device

    User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 22 of 27 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port.
  • Page 23 User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 23 of 27 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67B77 device. Warning: If Fig.
  • Page 24: Mechanical Dimensions

    User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 24 of 27 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 9: Mechanical dimensions scheme for HD67B77-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 25: Ordering Informations

    Enclosure Type A: 1M, 35mm DIN Rail mounting Device Family HD67B77: PROFINET Master / SNMP Agent - Converter Order Code: HD67B77-A1 PROFINET Master / SNMP Agent - Converter ACCESSORIES: Order Code: AC34011 Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V DC Order Code: AC34012 Rail DIN - Power Supply 220/240V AC 50/60Hz –...
  • Page 26: Disclaimer

    User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 26 of 27 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 27: Warranties And Technical Support

    User Manual PROFINET Master / SNMP Agent Document code: MN67B77_ENG Revision 1.000 Page 27 of 27 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

Table of Contents