Diagnostics Via Led Displays; Network Status Leds - Festo CPX-FB33 Operating Instructions Manual

Hide thumbs Also See for CPX-FB33:
Table of Contents

Advertisement

Diagnostics
The displayed diagnostic information is dependent on the settings on the bus node (è DIL Switch) as
well as on the parameterisation of the CPX terminal or the controller.
10.2

Diagnostics via LED displays

Various status LEDs are available for diagnostics at the bus node. They show hardware errors, config-
uration errors and bus errors directly on site, which enables fast error detection.
10.2.1

Network status LEDs

NE – Network Status/Network Error
LED
Sequence
LED is off
LED flashes
Tab. 16 Network status LED NE
M/P – Maintenance/PROFIenergy
LED
Sequence
LED is off
Festo — CPX-(M)-FB33/34/35/43/44/45 — 2020-04e
Status
No error
(if the PS LED is green)
Network connection not OK -
possible causes:
Only before initial start-up:
Configuration defective,
e.g. MAC-ID not configured
Device name or device num-
ber not correct
IO controller defective
Network connection inter-
rupted, short-circuited or
disturbed
Status
Maintenance action not
required, PROFIenergy function
not activated
Error handling
Check:
Configuration
Device name
Device number
IO controller
Network connection
Error handling