Alignment of Wired Infrared
Safety Sensors
WARNING
TO AVOID POSSIBLE SEVERE OR FATAL
INJURY, KEEP PEOPLE AND OBJECTS
CLEAR OF THE MOVING DOOR ARM TO
PREVENT POSSIBLE PERSONAL INJURY.
IMPORTANT: THE SAFETY SENSOR SENDS
AN INVISIBLE BEAM OF LIGHT FROM THE
SENDING UNIT TO THE RECEIVING UNIT
ACROSS THE PATHWAY OF THE DOOR. THE
OPENER WILL NOT OPERATE UNTIL THE
SAFETY SENSORS ARE CONNECTED TO THE
OPENER AND PROPERLY ALIGNED. IF THE
INVISIBLE BEAM OF LIGHT IS OBSTRUCTED,
AN OPEN DOOR CANNOT BE CLOSED BY
THE TRANSMITTER OR A MOMENTARY
ACTIVATION OF THE WALL STATION UP/
DOWN BUTTON. HOWEVER, THE DOOR MAY
BE CLOSED BY CONTINUOUSLY
HOLDING YOUR FINGER ON THE WALL
STATION UP/DOWN BUTTON (CONSTANT
PRESSURE) UNTIL THE DOOR TRAVELS TO A
FULLY CLOSED POSITION.
At this point you will be able to activate the
opener. The trolley/ upper arm will move
to the open position, but will not move to
the closed position unless the beams are
aligned.
The safety sensors must be aligned by
moving the sending and receiving units in or
out until the alignment light on the receiving
unit comes on. The 1/4"-20 carriage bolt
can be loosened to move the unit in or out,
as required. If you have difficulty
aligning beams, check that both brackets are
mounted at the same height (see Step 11)
and remount if necessary. Additional minor
adjustments can be made by lightly bending
the mounting brackets.
Once the alignment light comes on, tighten
all bolts and mounting screws.
Finish securing all wiring making sure not to
break or open any of the conductors. Loop
and secure any extra wire.
Using the wall station up/down button,
activate the opener and check that it will
operate through full open and close. Ensure
trolley and trolley latch are in the closed
position prior to proceeding to next step.
In
Out
1/4"-20 Carriage Bolts
For this adjustment, bend mounting brackets
Up/Down
Button
Wired Wall station
Up/Down
Button
Multi-Function Wall Station
at wall mount
Top View
Press
Here
RF Transmitter
In
Out

Advertisement

Table of Contents
loading

Table of Contents