• Control switching for continuous operation to torque control mode (ct)
To switch to continuous operation to the torque control mode (ct), the switching must be performed from the cyclic
synchronous position mode (csp) or cyclic synchronous velocity mode (csv). Only the "csp" and "csv" control modes switch to
"ct". To switch to "ct", set [Modes of operation (Obj. 6060h)] to "-104" while in the "csp" or "csv" control mode. Once the
condition for control switching is met, the control mode will switch to "ct", following which [Modes of operation display (Obj.
6061h)] is changed to "-104". If the condition is not met, the control mode will not be switched and the value in [Modes of
operation display] will not be changed. Continuous operation to torque control cannot be changed to "cst", "hm", etc. Refer to
the following table for details.
[Modes of operation] = 8
CSP mode
[Modes of operation display] = 8
[Modes of operation] = 8
PP mode
[Modes of operation display] = 1
Switching operation
(1)
Cyclic synchronous position mode → Cyclic synchronous torque mode
(2)
Cyclic synchronous position mode → Continuous operation to torque control mode
(3)
Cyclic synchronous torque mode, Continuous operation to torque control mode → Cyclic
synchronous position mode
(4)
Cyclic synchronous velocity mode → Cyclic synchronous torque mode, Continuous operation
to torque control mode
(5)
Cyclic synchronous torque mode, Continuous operation to torque control mode → Cyclic
synchronous velocity mode
(6)
Cyclic synchronous position mode → Cyclic synchronous velocity mode
(7)
Cyclic synchronous velocity mode → Cyclic synchronous position mode
*1 The state where S_ZSP (Bit 3 of [Status DO 2 (Obj. 2D12h)]) is turned on. (servo motor speed being less than zero speed set in [Pr.
PC07])
2 APPENDIX
44
2.1 CC-Link IE TSN
(3)
[Modes of operation display] = 10
(1)
[Modes of operation] = 10
[Modes of operation] = 9
[Modes of operation] = 8
[Modes of operation] = -104
(2)
(3)
[Modes of operation display] = -104
The continuous operation to torque control mode cannot be changed to the profile modes.
[Modes of operation display] = 3
CST mode
[Modes of operation] = 10
(6)
(7)
[Modes of operation] = -104
Continuous operation
to torque control mode
PV mode
(5)
[Modes of operation] = 9
(4)
CSV mode
[Modes of operation display] = 9
(4)
[Modes of operation] = 9
(5)
TQ mode
[Modes of operation display] = 4
Switching condition
*1
Servo motor being stopped
No condition
*1
Servo motor being stopped
No condition
*1
Servo motor being stopped
*1
Servo motor being stopped

Advertisement

Table of Contents
loading

Table of Contents