Application Function; Cc-Link Ie Tsn Network Diagnostics - Mitsubishi Electric MELSERVO-JET MR-JET-G User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-JET MR-JET-G:
Table of Contents

Advertisement

1.3

Application function

CC-Link IE TSN Network diagnostics

The servo amplifier supports the following CC-Link IE TSN Network diagnostic functions. Check the reference destination in
the reference column for precautions specific to the servo amplifier. Refer to the GX Works3 manual for details of other
functions.
Function type
Monitoring function of
network status
Setting change function
of network status
Selected Station
Operation
Selected station communication status monitor
The detailed state of the currently selectable device on the network map monitor is displayed on the selected station
communication status monitor. The items displayed on the selected station communication status monitor are shown below.
Setting item
Status display
CC-Link IE TSN status display
In the selected station communication status monitor, CN1A is displayed as PORT2, and CN1B as PORT1.
Remote Operation
The only executable function on servo amplifiers is Reset. When Reset is executed to the servo amplifier, the servo amplifier
resets the software. For details on software reset, refer to the following.
MR-JET User's Manual (Function)
1 CC-Link IE TSN
12
1.3 Application function
Function
Description
Network map monitor
The current network connection configuration is displayed as a diagram.
Information such as the connection status of cables, duplication of IP
address, and the disconnection status of stations can be monitored.
The error history stored in the servo amplifier can be read and deleted.
These operations can be performed by servo amplifiers with firmware
version B2 or later.
Selected station
The details of the unit status and the communication status of the selected
communication status
station are displayed. If an error occurs in the unit, the cause of the error
monitor
and its remedies can be checked.
Reserved station
This function designates a specified station as a reserved station, or
specification/
cancels it.
cancellation
Remote Operation
A reset command can be sent to the specified station.
Description
The status of the servo amplifier is displayed via LED.
The CC-Link IE TSN status (CN1A/CN1B connector LED) is displayed.
Reference
Page 12 Selected
station communication
status monitor
Page 12 Remote
Operation
Reference
MR-JET-G
User's Manual
(Introduction)

Advertisement

Table of Contents
loading