WARNING: The voltage parameters of a lithium battery can be set according
to the voltage parameters of lithium battery BMS.
WARNING: The required accuracy of BMS shall be no higher than 0.2V. We
will not assume any responsibility for the system abnormal when the
accuracy of BMS is higher than 0.2 v.

2.5 Load output voltage and priority setting

Load 2
L2
Output voltage
Load 1
L1
Output voltage
Load working
Modes
(only valid for load 2)
The load prior mode will be enabled when the battery voltage reaches the low voltage disconnect
voltage, and the PV array charging current reaches more than 7A for 10 minutes.
WARNING: Before connecting loads, ensure the voltage level of load is
equal to the output voltage level corresponding to the DIP switch. If the
output voltage level is higher than the load voltage, the load may be
damaged.
Set to OFF
Set to ON
Set to OFF
Set to ON
Charging prior mode (Default)
Set to OFF
Set to ON
13
Output 12V
Output 24V
Output 12V
Output 24V
CPM(Charging Prior Mode)
Load prior mode
LPM(Load Prior Mode)