FT-70/75 Fill Level Inspectors Operator's Guide
Error Number 27
Containers are passing the inspection station, but the encoder is
not sending pulses: at least 5 consecutive inspection triggers
occurred without sensor transition. Report this error to your
Service Department.
Error Numbers 28
These error pertains to label inspection. Report this error to your
Service Department.
Error Number 33
This error occurs when the number of consecutively rejected
smashed containers exceeds the limit set in the Consecutive
Smashed Bottle Reject Alarm function. Report this error to your
Service Department.
Error Number 34
Two or more consecutive inspection triggers have occurred with
no Smashed Bottle sensor transition. Report this error to your
Service Department.
Error Number 46
The number of containers in the Consecutive External Reject
Alarm was exceeded. This is a high priority error condition and
will cause the Warning Beacon to flash if Beacon Status is set to
HIGH PRIORITY ONLY. If this error persists, report this error to
your Service Department.
Error Number 47
Report this error to your Service Department.
Error Number 48
The AC input voltage dropped below 90 volts on a 110 VAC system
or below 185 volts on a 220 VAC system. During the time the
voltage was low, no containers were inspected for any defect.
When the power returns to normal, the system resets with no data
being lost. This is a high priority error condition and will cause the
Warning Beacon to flash if Beacon Status is set to HIGH PRIORITY
ONLY. If this error persists, report this error to your Service
Department.
4-8
Industrial Dynamics Company, Ltd. Document 40274-0600