Filtec FT-70 Operation Manual page 27

Fill level inspectors
Table of Contents

Advertisement

FT-70/75 Fill Level Inspectors Operator's Guide
No.
Description
1
Head Height Adjustment Crank
2
Head Height Counter
3
Centerline Trigger Bracket Height Adjustment Crank
4
X-ray Safety Interlock Switch
5
Centerline Trigger Height Adjustment Scale
6
Centerline Trigger Bracket
7
Centerline Trigger Bracket Height Lock
8
Head Height Lock
2-6
6 6 6
Figure 2-3. The FT-70/75 adjustment mechanisms.
2. Loosen the Head Height Lock and, using the Head Height
Adjustment Crank, adjust the head height as follows:
• If the new setting is above the previous setting, crank the
head up until the Head Height Counter indicates you have
reached the correct height.
• If the new setting is below the previous setting, crank the
head below the new setting about 20 ticks and then back up
until the Head Height Counter indicates you have reached
the correct height. This will eliminated any backlash in the
raising mechanism.
3. Tighten the Head Height Lock to secure the position.
Industrial Dynamics Company, Ltd. Document 40274-0600
3
1
2
5
5
1
3
?
2
4
6
7
8
4
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ft-75

Table of Contents