FT-70/75 Fill Level Inspectors Operator's Guide
Note
Note
2-20
The Bulged Lid Sensor is mounted on a u upstream offset bracket
attached to the Centerline Trigger Bracket. Therefore before you
align Bulged Lid Sensor, be certain the Centerline Trigger Bracket
is aligned properly. For more information see "Adjusting the
Centerline Trigger Bracket Height" on page 2-7.
Bulged Can detection is only available when the containers are
oriented in top-up position.
1. Turn off the Safety Interlock Switch. For more information see
"The Safety Interlock Switch" on page 2-4.
2. Center a properly filled and sealed production container under
the downstream sensor mounting bracket.
3. Loosen the downstream sensor mounting bracket adjustment
knob and adjust the sensor so that it is 1mm above the
container lid.
If you do not have enough adjustment range to position the sensor
correctly, reposition the sensor receiver and emitter in the bracket
by moving it up or down enough hole positions to give you the
range you need.
4. Tighten the adjustment knob to secure the positioning.
5. If you will not be performing further alignment procedures,
reactivate the X-ray Generator. For more information see "The
Safety Interlock Switch" on page 2-4.
Industrial Dynamics Company, Ltd. Document 40274-0600