Your Hayward Super II ECO Single Speed Pump is specifically engineered for the demanding requirements of today's in-ground/above
ground swimming pool/spa that is equipped with large capacity filters, heaters, and pool cleaning equipment. The self-priming centrifugal
pump has been quality-built and engineered to give you many years of efficient, dependable, corrosion free service. The advanced design
reduces operation and maintenance to simple, commonsensical procedures.
D

Product Dimensions

9.458
C
309
B
7.625
8.635
A
8
8
7

Pump Location

Top View
Side View

Pump Mounting

Install pump on a level concrete slab or other rigid base to meet all local and national codes.
Secure pump to base with screws or bolts to further reduce vibration and stress on pipe joints.
The base must be level, rigid, and vibration free.
Pump mount must:
» Allow pump inlet height to be as close to water level as possible.
» Allow use of a short, direct suction pipe (to reduce friction losses).
» Allow for valves in suction and discharge piping.
» Be protected from excess moisture and flooding.
» Allow adequate access for servicing the pump and piping.
*NOTE: It is recommended that a minimum length of straight piping (shown as "L" in diagram to the right), equivalent to 5 pipe size diameters,
be used between the pump suction inlet and any plumbing fittings (elbows, valves, ect).
4
INTRODUCTION
240
9.458
12.149
207
8.154
7.625
219
8.635
7
6
6
5

INSTALLATION

WARNING – This product should be installed and serviced only by a qualified professional.
Locate the pump as practically close to the pool as possible. Run the suction line as directly as possible,
from pump to pool, in order to reduce friction losses. The suction line should have a continuous slope
upward from lowest point in line. Joints must be tight (but not over-tightened). The suction line must not
be smaller than 40 mm PVC and must be equal to or larger in diameter than the discharge line diameter.
Though the pump is designed for outdoor use, it is advised to place pump and filter in the shade to shield
them from continuous direct heat. Select a well-drained area that will not flood when it rains. Do NOT
install pump and filter in a damp or non-ventilated location. Keep motor clean. Pump motors require free
circulation of air for cooling. The maximum Suction Lift with out a check valve installed in the suction piping
where the pump can still prime is 1.8 metres.
USE ONLY HAYWARD® GENUINE REPLACEMENT PARTS
351
13.817
10.392
264
10.392
12.149
8.154
10.017
10.017
SIIE 530 & 580 = 618
18.866
SIIE 350 & 430 = 594
SIIE 320 = 569
All dimensions in millimeters
5
4
13.817
18.866
24.348
24.348
4
3
3
2
F
E
D
C
SIIE 530 & 580 = 263
10.358
10.358
SIIE 320, 350 & 430 = 246
B
A
NAME
DATE
2017/1/10
NAME
DATE
MODELED
MODELED
2017/1/10
DRAWN
R
2017/8/18
DRAWN
2017/8/18
CHECKED
CHECKED
ENG APPR.
DESCRIPTION:
ENG APPR.
DESCRIPTION:
MFG APPR.
MFG APPR.
MATERIAL:
Q.A.
SIZE
DWG. NO.
E
MATERIAL:
SEE PART DRAWINGS
DWG. NO.
REV
Q.A.
SIZE
E
SEE PART DRAWINGS
WEIGHT:
74.44 LBS.
74.44 LBS.
SEE PART DRAWINGS
SCALE: 1:1
SHEET 1 OF
WEIGHT:
COLOR:
STATUS:
SCALE: 1:1
SHEET 1 OF 1
COLOR:
SEE PART DRAWINGS
UNAUTHORIZED USE, MANUFACTURE, OR REPRODUCTION IN WHOLE OR IN PART IS PROHIBITED. DRAWING, DESIGN, AND OTHER DISCLOSURES A
UNAUTHORIZED USE, MANUFACTURE, OR REPRODUCTION IN WHOLE OR IN PART IS PROHIBITED. DRAWING, DESIGN, AND OTHER DISCLOSURES ARE PROPERTY OF: HAYWARD POOL PRODUCTS
2
1
1
" L "

Advertisement

Table of Contents
loading

Table of Contents