Super Pump
Basic safety precautions should always be followed, including the following: Failure to follow instructions
can cause severe injury and/or death.
This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for
one of the following signal words and be alert to the potential for personal injury.
WARNING
warns about hazards that could cause serious personal injury, death or major property
damage and if ignored presents a potential hazard.
CAUTION
warns about hazards that will or can cause minor or moderate personal injury and/or
property damage and if ignored presents a potential hazard. It can also make consumers aware of
actions that are unpredictable and unsafe.
The NOTICE label indicates special instructions that are important but not related to hazards.
Owner's Manual
IMPORTANT SAFETY INSTRUCTIONS
Hayward Pool Products
620 Division Street, Elizabeth, NJ 07207
Phone: (908) 355-7995
www.hayward.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
700 Series
®
Contents
Introduction.................................4
Installation...................................7
Replacement Parts.....................10
Troubleshooting.........................11
Warranty.......................................13
Registration ................................15
IS26700T Rev-A
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Super Pump 700 Series and is the answer not in the manual?

Questions and answers

Ronald Gauvreau
August 4, 2025

Iwould like to have the wiring for the installation the capaciter model c48l2nl34b3 serial 08218ch

Summary of Contents for Hayward Super Pump 700 Series

  • Page 1: Table Of Contents

    It can also make consumers aware of actions that are unpredictable and unsafe. The NOTICE label indicates special instructions that are important but not related to hazards. Hayward Pool Products 620 Division Street, Elizabeth, NJ 07207 Phone: (908) 355-7995 www.hayward.com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 2: Product Specific Warnings

    Use only y a low pressur e (below 5 PSI) high volum me blower when air purging the e pump, filter, o or piping. USE ONLY Y HAYWARD G ENUINE REPLA ACEMENT PAR...
  • Page 3 Unawareness of impending danger. Failure to perceive heat. Failure to recognize the need to leave the spa. Physical inability to exit the spa. Fetal damage in pregnant women. Unconsciousness resulting in danger of drowning. SAVE THESE INSTRUCTIONS USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 4: Introduction

    General Information Introduction This manual contains information for the proper installation and operation of the Hayward Super Pump ® 700 Series. The instructions in this manual MUST be followed precisely. Failure to install according to defined instructions will void warranty.
  • Page 5 Insure that the electrical supply available agrees with the motor’s voltage, phase, and cycle, and that the wire size is adequate for the HP (kW) rating and distance from the power source. NOTE - All electrical wiring MUST be performed by a licensed electrician, and MUST conform to local codes and NEC regulations USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 6 (except gas piping), and conduit within 5 ft. (1.5 m) of inside walls of swimming pool, spa, or hot tub. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 7 If pump does NOT prime within five minutes, stop motor and determine cause. Be sure all suction and discharge valves are open when pump is running. See Troubleshooting Guide. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 8: Shaft Seal Replacement

    Keep motor clean. Insure air vents are free from obstruction to avoid damage. Do NOT use water to hose off motor.  Occasionally, shaft seals must be replaced, due to wear or damage. Replace with genuine Hayward seal assembly kit. See “Shaft Seal Change Instructions” in this manual. Storage/Winterization WARNING –...
  • Page 9: Installation

    Only qualified personnel should attempt rotary seal replacement. Contact your local authorized Hayward Dealer or service center if you have any questions. Exercise extreme care in handling both the rotating and the stationary sections of the two-part replacement seal. Foreign matter or improper handling will easily scratch the graphite and ceramic sealing surfaces.
  • Page 10: Replacement Parts

    SPX1600Z4 SPX1600Z4 MOTOR CAP SCREW SPX125Z4 SPX125Z4 MOUNTING FOOT [WILL INCLUDE SCREWS( ITEM #18)] SPX2600G1 SPX2600G1 MOUNTING FOOT CAP SCREW SPX1600J SPX1600J SLINGER SPX0125F SPX0125F MOTOR- TEFC [WILL INCLUDE SLINGER (ITEM #19)] SPX2607Z1MTG SPX2610Z1MTG USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 11: Troubleshooting

    Solution: Contact qualified professional to check that the wiring gauge is heavy enough. NOTE Your Hayward pump motor is equipped with an “automatic thermal overload protector.” The motor will automatically shut off if power supply drops before heat damage can build up causing windings to burn out. The “thermal overload protector”...
  • Page 12 4. Motor bearings noisy from normal wear, rust, overheating, or concentration of chemicals causing seal damage which will allow chlorinated water to seep into bearings wiping out the grease causing bearing to whine. Solution: All seal leaks should be replaced at once. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 13: Warranty

    The express limited warranty above constitutes the entire warranty of Hayward Pool Products with respect to its’ pool products and is in lieu of all other warranties expressed or implied, including warranties of merchantability or fitness for a particular purpose. In no event shall Hayward Pool products be responsible for any consequential, special or incidental damages of any nature.
  • Page 14 This page left blank intentionally USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 15: Registration

    USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 16 Ground Or R REGISTER YOU R WARRANTY ON-LINE AT W WWW.HAYWAR RD.COM Hayward and Super Pump are registered trademark ks of Hayward Indust tries, Inc. © 2018 H ayward Industries, In USE ONLY H HAYWARD GEN NUINE REPLAC CEMENT PART...