Stratasys Dimension BST 768 Quick Start Manual page 2

Head clog clearing

Advertisement

Step 2:
-
Open the Head by unscrewing the
two quarter turn screws to the left
side of the head (circled in red)
Step 3:
-
Slowly open the head
-
Remove any clogged material and
cut the material off that is feeding
into the head
-
After removing the material you
can see, unscrew the Feed Funnel
pictured to the right
Step 4:
-
Wearing protective gloves
(included in the Welcome Kit),
remove the Feed Funnel and set
aside