Wayne Jet Pump JSU50 Operating And Parts Manual page 3

Jet pump
Hide thumbs Also See for Jet Pump JSU50:
Table of Contents

Advertisement

Manual de Instrucciones de Operación y Piezas
Figura 11 - Suministros de agua
22 Sp
Operating Instructions and Parts Manual
JSU50
Installation
8. Slope horizontal lines up toward
pump a minimum of 1/4" per foot.
This will prevent trapping air in the
lines.
ELECTRICAL CONNECTIONS
The voltage of power supply must
match the voltage of the pump. Above
ground well pumps covered in this
manual have dual voltage motors pre-
set at the factory to 230 volts. The
motors can be converted to 115 volts by
turning the voltage selector to the
desired voltage (See Figure 6). Use a
needle nose pliers to pull the selector
out approximately 1/4", rotate and
then reinsert in correct position.
230 V
115 V
115 V
Figure 6 - Voltage Selector
Connect the pump to a separate electri-
cal circuit with a dedicated circuit
breaker. Refer to the electrical specifi-
cations in the Wiring Chart for recom-
mended circuit breaker and wire size.
Install and main–
WARNING
!
tain wiring for this
pump in accordance with the National
Electrical Code and all applicable local
codes.
The motor must be grounded by con-
necting a copper conductor to the
grounding screw provided within the
wiring compartment in the pressure
switch.
The field wiring compartment for the
jet pump is inside the pressure switch
housing. There is only one proper
ground screw on the unit. The screw is
located under the pressure switch
cover, painted green and is identified
as GRD. The ground connection must
be made to this terminal (Figure 7).
(Continued)
Motor
1
3
L1 L1
L2 L2
Attach
Ground
Wire
Here
Figure 7 - Electrical Connections
Refer to the wiring diagram located
under the cover of the pressure switch
(Figure 7).
To attach AC power to the switch,
loosen the screw holding the cover
onto the switch and remove the cover.
Loosen unused ground screw and
attach the exposed end of the ground
wire between the screw head and the
pressure switch body, then tighten.
Loosen the top two screws on the pres-
sure switch and retighten with the AC
power leads captured under the screw
heads. Reattach the pressure switch
cover and tighten the screw.
CONNECTION TO WATER SOURCE
230 V
DRIVEN WELL
1. Drive the point several feet below
the water table.
NOTE: A packer-type foot valve can be
installed in the well (Figure 8). This
type of foot valve allows the well pipe
to be filled with water when priming
and makes the inlet pipe much easier
to test for leaks. Follow the manufac-
turer's instructions when installing the
packer-type foot valve.
To pump
Drive
Packer Type
Point
Foot Valve
Figure 8 - Packer-Type Foot Valve
3
JSU50
To
pump
Inline
check
valve
Line
Drive
Point
Figure 9 - In-Line Check Valve
As an alternative, an in-line check valve
can be used with a driven well (Figure
9).
Do not use both a
NOTICE
check valve and
foot valve in your system. This could
significantly reduce the performance of
the pump.
DRILLED WELL
1. Install a foot valve on the first sec-
tion of pipe (Figure 10).
To
pump
Well seal
Well casing
Foot valve
Figure 10 - Well Seal
2. Lower the pipe into the well.
3. Add pipe until the foot valve is 10
feet below the lowest anticipated
water level.
Leaking joints or couplings will allow
air to leak into the pipe and cause poor
pump operation. Make sure to use pipe
joint compound or Teflon
®
tape on all
pipe connections.
Locate foot valve
CAUTION
!
at least 2 feet from
the bottom of the well so sand or sedi-
ment is not drawn into the system.
www.waynepumps.com

Advertisement

Table of Contents
loading

Table of Contents