Safety; Correct Use; Safety Instructions; Ce Designation - STIEBEL ELTRON PSH 30 COMFORT Operation And Installation

Wall mounted dhw cylinder
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
operation

Safety

2
Safety
2.1

correct use

The appliance is exclusively designed for heating domestic hot
water (DHW).
Any other use beyond that described shall be deemed inappropriate.
It is not permissible to heat other liquids or materials.
Observation of these instructions is also part of the correct use
of this appliance.
2.2

Safety instructions

observe the following safety information and instructions.
All steps up to the commissioning of this appliance must only be
carried out by qualified contractors.
The electrical installation and installation of the water connection
must only be carried out by a qualified contractor or by our
customer service engineers.
The contractor is responsible for adherence to all currently
applicable regulations during installation and commissioning.
Operate this appliance only if it is fully installed and all safety
equipment is fitted.
Risk of scalding.
The hot water at the tap can reach a temperature
of up to 80 °C. There is a risk of scalding at outlet
temperatures in excess of 43 °C. Small children
should be kept away from the taps.
Risk of injury!
Where children or persons with limited physical,
sensory or mental capabilities are to be allowed
to control this appliance, ensure that this will only
happen under supervision or after appropriate
instructions by a person responsible for their safety.
Children should be supervised to ensure that they
never play with the appliance.
2.3

ce designation

The CE designation shows that the appliance meets all essential
requirements according to the:
Electromagnetic Compatibility Directive
Low Voltage Directive
The type plate is located at the bottom of the appliance.
3

Appliance description

The wall mounted DHW cylinder constantly maintains the DHW at
the pre-selected temperature. The water is heated by the electrical
heating element. You can additionally switch on the second heating
element with the pushbutton and reduce the heat-up time. The
second heating element is switched off when the set temperature
has been reached.
The expansion water that collects as the water is heated up is
drained off via the safety valve. The inner cylinder of the DHW
cylinder is protected against corrosion by an enamel coating in
conjunction with the integral protective magnesium anode.
www.stiebel-eltron.com
4
Operation
4.1

other relevant documents

For operation, also observe the operating instructions of the
relevant accessories and any appliance documentation.
4.2

user interface

The appliance is operated using the temperature selector and the
pushbutton on the user interface.
User interface
1
2
1
Temperature selector
2
ON/OFF indicator
3
Pushbutton for additional output
Risk of damage
!
Only the contractor is permitted to remove the
thermostat button.
4.3

adjustment options

4.3.1
Temperature adjustment
By turning the temperature selector, you can select the temperature
of the water in the DHW cylinder. Turn it clockwise to raise the
temperature, and anti-clockwise to lower the temperature.
Frost protection setting
E
Economy setting at approx. 40 °C
e
Economy setting at approx. 60 °C
Maximum temperature at approx. 80 °C
As soon as the temperature of the water in the DHW cylinder drops
below the set value, the heating element automatically switches
on. The ON/OFF indicator illuminates until reheating is complete
and the set temperature has been reached again.
4.4

output

You can increase the output using the pushbutton, located at
the bottom right next to the temperature selector. Pressing the
pushbutton switches on a second, additional heating element.
4.5

recommended settings

4.5.1
Water temperature
The water temperature is continuously variable, and can be set
subject to your requirements. The setting range extends from
approx. 7 °C to approx. 80 °C.
3
PSH Comfort |
13

Advertisement

Table of Contents
loading

Table of Contents