IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-10
IEC 61000-4-11
IEC 61000-4-16
IEC 61000-4-17
RUGGEDCOM RST2228
Installation Manual, 08/2020, C79000-G8976-1359-10
If the unit contains all fiber ports, the IEC 61850-3 and IEEE 1613 conformance is
Class 2, during which no disturbance errors will occur.
Test
ESD
Radiated RFI
Burst (Fast
Transient)
Surge
Induced
(Conducted) RFI
Magnetic Field
Damped
Oscillating
Magnetic Field
Voltage Dips
and Interrupts
Mains Frequency
Voltage
Ripple on DC
Power Supply
6.2 EMC and Environmental Type Tests
Description
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Enclosure Ports
Enclosure Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
DC Power Ports
Certification
Test Levels
Severity Levels
± 8 kV
± 15 kV
20 V/m
± 4 kV at 2.5
and 5 kHz
± 4 kV at 2.5
and 5 kHz
± 4 kV at 2.5
and 5 kHz
± 4 kV at 5 kHz
± 4 kV Line-
to-Earth
± 2 kV Line-to-Line
± 2 kV Line-
to-Earth, ± 1
kV Line-to-Line
± 4 kV Line-
to-Earth
± 2 kV Line-to-Line
10 V
10 V
10 V
10 V
100 A/m for 3 min
1000 A/m for 1 s
100 A/m for
1 s (100 kHz
and 1 MHz)
30% for 1 period
60% for 50 periods
100% for 5 periods
100% for
50 periods
30 V for 60 s
300 V for 1 s
30 V for 60 s
300 V for 1 s
30 V for 60 s
300 V for 1 s
15%
4
4
a
Note
a
Note
4
4
4
4
3
4
3
3
3
3
5
5
 
4
4
4
3
43