TTYCSLA-1Q cable (NMEA0183 connection)
Armor
Clamp this part with the
cable securing plate.
How to connect wires to a terminal block connector
Twist
2.1.4
How to change the fuse
Change the fuse in the fuse holder on the power cable
according to the input voltage, referring to the following
table. Fuses are supplied as spare parts.
Note: For the power cable of the transceiver unit, it is not
required to change the fuse.
Inner sheath
Pass a heat shrinkable tube (supplied
locally) onto the drain wire.
Vinyl tape
Attach a crimp-on lug (FV1.25-3,
supplied locally) to the core.
Press downward.
Terminal
opener
Terminal block
connector
Use the proper fuse.
Fuse rating is shown in the table below.
Use of a wrong fuse can result in
damage to the equipment.
Input voltage
12 VDC
24 VDC
495 mm
495 mm
450 mm
450 mm
Drain wire
Drain wire
6 mm
6 mm
80 mm
80 mm
6 mm
6 mm
Procedure
1. Twist the cores.
2. Press the terminal opener
downward.
3. Insert the wire in the hole.
4. Remove the terminal
opener.
5. Pull the wire to confirm
that it is secure.
WARNING
15 A (factory default)
2. WIRING
Fuse holder
Power cable
Rating of fuse
7 A
2-5