Troubleshooting

Inputs and Outputs

PLC Outputs

Go to the main menu and select INPUT/OUTPUT TEST and the screen will change to the
first test screen. Press on an output selection to test, below is an example of the BRUSH
LIFT test. The Brush Lift test also shows the inputs that control the motor to stop in the
proper position. When testing the motor you are also testing and watching for correct
switch operation at the same time.
To check inputs, press on one of the two input screens to view. The inputs that are on
will change color to yellow. To test an input you will need to physically operate the
switch by pressing on it or pass metal by a proximity sensor.
Here is a list of the OUTPUT numbers for the PLC along with their, wire color, and designations
OUTPUT
100.00
100.01
100.02
100.03
100.07
100.06
101.00
101.01
101.02
101.03
101.04
101.05
101.07
CHAPTER
DESCRIPTION
OIL CONTROL VALVE
POWER OFF RELAY (
NOT A TEST
FORWARD DRIVE
REVERSE DRIVE
BUFFER MOTOR
OIL PUMP MOTOR
MOVING HEAD MOTOR DIRECTION (
MOVING HEAD MOTOR RUN
BRUSH LIFT MOTOR
SQUEEGEE MOTOR
DUSTER UNWIND
DUSTER WIND-UP
VACUUM MOTOR
62
7
WIRE COLOR
ORANGE
)
GRAY/YELLOW
GREEN / ORANGE
YELLOW / VIOLET
YELLOW / BLUE
GRAY/VIOLET
) VIOLET/RED
NOT A TEST
VIOLET/ORANGE
WHITE / BLACK
BLUE / WHITE
GREEN / BLUE
GREEN / RED
BLUE / BLACK
.