Error Code [7130] - Mitsubishi Electric PUHY-P250YNW-A Service Handbook

Hide thumbs Also See for PUHY-P250YNW-A:
Table of Contents

Advertisement

[7-9 Error Code Definitions and Solutions: Codes [7000 - 7999] ]
7-9-8
Error Code [7113]
1. Error code definition
Function setting error (improper connection of CNTYP)
2. Error source, cause, check method and remedy
Error source
Outdoor unit
(1)
Wiring fault
(2)
Loose connectors, short-cir-
cuit, contact failure
(3)
Incompatible control board
and INV board (replacement
with a wrong circuit board)
(4)
DIP SW setting error on the
control board
62
- chapter 7
Cause
(Detail code 15)
1) Check the connector CNTYP5 on the control board for proper con-
nection.
2) Check the connector CNTYP4 on the control board for proper con-
nection.
(Detail code 14)
1) Check the connector CNTYP4 on the control board for proper con-
nection.
2) Check the settings of SW5-3 through SW5-6 on the control board.
(Detail code 12)
1) Check the connector CNTYP2 on the control board for proper con-
nection.
2) Check the connector CNTYP5 on the control board for proper con-
nection.
3) Check the settings of SW5-3 through SW5-6 on the control board.
(Detail code 16)
1) Check the connector CNTYP on the INV board for proper connec-
tion.
2) Check the connector CNTYP5 on the control board for proper con-
nection.
3) Check the settings of SW5-3 through SW5-6 on the control board.
4) Check the wiring between the control board and INV board.
Refer to the following page(s). [7-2-1 Error Code [0403]]
(Detail code 0, 1, 5, 6)
1) Check the wiring between the control board and INV board.
Refer to the following page(s). [7-2-1 Error Code [0403]]
2) Check the settings of SW5-3 through SW5-6 on the control board.
3) Check the connector CNTYP5 on the control board for proper con-
nection.
(Detail code Miscellaneous)
*If a set-model-name identification error occurs, check the detail
code on the unit on which the error occurred. The detail code that
appears on other units will be different from the ones shown
above.
Check method and remedy
BS_07_C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Puhy-p500ysnw-aPfd-p250vm-ePfd-p500vm-e

Table of Contents