Floor Requirements
The tire changer should be placed on a solid concrete floor. Any floor condition which might allow the tire changer
to move during operation is unacceptable. The depth of the flooring must guarantee anchor bolts will hold firmly.
If the location selected is a cement floor that is hollow underneath, place the tire changer over a supporting beam
or close to a supporting wall.
Power Requirements
The customer must furnish 230VAC, 60 HZ, service for maximum 12 AMP draw, single-phase power for the
TCA28.
Power source requirements of TCA28 are located on the Hunter serial number plate.
Changes to the AC power cord, plug and/or power source must be performed by a certified electrician.
Air Requirements
The customer must furnish compressed air at 145 ± 30psi. The customer must furnish an air supply line with a 1/4
inch NPT female fitting to connect to the tire changer.
Assembly Procedures
Unpack the Tire Changer
1. Place the skid near the installation location (Fig. 1).
Fig. 1
2. Remove staples and straps securing carton to pallet. Remove carton.
3. Remove protective plastic covering from pallet and tire changer.