Clearances - Montigo H34VO Series Installation & Maintenance Manual

Divine outdoor residential gas fireplace
Table of Contents

Advertisement

Divine Outdoor Gas Fireplace
Section 2: Framing
Choosing The Fireplace Location
The Divine Outdoor VO may be installed in an outdoor setting such as
a patio or balcony. Choose a location that maintains proper clearance
to combustibles as noted in the clearances chart.
Note: Divine Outdoor VO may not be recessed into the exterior wall.
Note: Minimum 2 side of the covered patio/deck must be open
Figure 2. Choosing the fireplace location.
For protection against freezing temperatures, it is recommended that
outer walls of the chase be insulated with a vapour barrier. This will
reduce the possibility of a cold-air convection current on the fireplace.
M"
** Optiona lD rain Pan:
available for all models.
H34VO Part No. OD34123
N"
H38VO Part No. OD38123
H42VO Part No. OD42123
Figure 2a. Framing dimensions.
Framing Dimensions
H34VON
H38VON
H42VON
** The Divine Outdoor VO models have an Optional Stainless Steel
Drain Pan available. Note, If the Drain Pan is ordered with the fireplace
it must be installed at the time of construction. The Pan cannot be
added at a later date. See Figure 2a above.
Page 6
Installation
Exterior Wall
Insulation material
vapor barrier
(exterior wall).
O"
B
M
N
O
P
Q
40⅜" 33⅞" 20¾" 73⅝" 52"
43⅜" 37⅞" 21"
79
55⅞
46¾" 42" 22⅝" 85"
60"
Warning:
When covering the upper metal portion of the fireplace with a non-
combustible material Please Note: The decorative facing materials
may be subject to temperatures in excess of 250° F. This should be
considered when selecting facing materials.
Please be aware; temperatures over the mantel will rise above normal
room temperature and walls above fireplace may be hot to touch.
We recommend careful consideration be given to the effects of elevated
mantel temperatures which may be in excess of product design, for
example: candles, plastic or pictures.
When installing a shelf over the top of the fireplace, the minimum
clearance from the top of the fireplace to a shelf is 9".
When raising the hearth, the minimum clearance from the top of the
fireplace to a combustible ceiling is 36".
M"
** Optiona l Drain Pan:
available for all models.
H34VO Part No. OD34123
H38VO Part No. OD38123
H42VO Part No. OD42123
9"
S
M
Figure 2b. Framing for shelves over the fireplace.

Clearances

The Divine Outdoor VO clearances to combustible materials are listed
below and are the minimum clearances to combustibles that apply to
Top View
the following dimensions:
C
D
Q"
D
I
Figure 3. Minimum Corner framing dimensions.
A
Front View
If the Optional drain pan is not used during construction; (as shown
in Figure 2a above) ensure any water build-up can escape to the
exterior of the finished enclosure.
Water penetration can occur, and accumulate in the base of the
fireplace, and if not taken into consideration can cause deterioration
of materials, and may cause premature failure of the structure.
Insulation material
vapor barrier
(exterior wall).
N"
O"
Clearances
H34VON
H
12"
Mantel
Shelf*
9"
* Dimension plus height of shelf.
G
A
1" clearance
to corners only
D
F
N"
P"
E
B
1" Clearance to
combustibles to sides
ot Unit
F
Side View
Important
Q"
H38VON
H42VON
12"
12"
9"
9"
G
J
XG0150 - 140707.2